100% Original Factory Miniature Circuit Breaker FTB2-63 for Zimbabwe Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Well-run equipment, professional sales team, and better after-sales services; We are also a unified big family, everyone stick to the company value "unification, dedication, tolerance" for 100% Original Factory Miniature Circuit Breaker FTB2-63 for Zimbabwe Factory, We warmly welcome all perspective inquiries from home and abroad to cooperate with us, and look forward to your correspondence.


Product illustration

gagwq

Technical Data

Model FTB2-63 Miniature circuit-breaker
Number of poles IP 2P 3P 4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

1,2,3,4, 6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated breaking capacity(KA) 6.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2 , Cross-section of busbar from 0.8- 2mm2,reversibility of connections
Tightening torque 2 Nm
Ambient temperature ( C) -5 C ~ +40 C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 102 208 308 408

Product Feature

- These circuit breakers are intended for the protection of circuits against overloads and short circuits in residential, commercial and industrial premises;

- It covers the rating range from 6 to 63A with a uniform breaking capacity of 6.5 kA throughout;

- Current-limiting scheme: in the event of a short circuit, are able to limit the let-through current to 60%-70%  of the rated current;

- The arc extinguishing system: allows the short-circuit currents of very high value to be interrupted extremely rapidly, the remarkable opening speed of contacts opening and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time;

-The sensitivity and reliability of the trip mechanism ensures perfect closure every time,thereby considerably improving the performance of these devices and extending their average lifetime;

- The internal contact position allows an exact information of the circuit-breaker status:“green”, open contacts;“red”, closed contacts,independently of the toggle position;

- Sealing/locking sealable with 1 mm wire , to prevent unwanted  tripping;

- The supply lines of the protected circuit can be connected to either the upper or lower terminals of the circuit-breakers(reversibility of connections). The double terminal of these circuit-breakers enables simultaneous connection of cables and busbars.

 

Tripping characteristic

qrgadg qweq

Exterior and dimensions

agg

Unit(mm)

Number of poles 1P 2P 3P 4P
a 80±0.8
b 74.2±0.8 75.7±0.8
c 17.8±0.5 35.6±0.8 53.4±0.8 71.2±0.8
d 44±0.8
e 68.7±0.8 70.2±0.8
f 45±0.8
g 35.5±0.8

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A) Nominal cross section area of copper wire(mm2 )
1~6 1
10 1.5
16,20 2.5
25 4
32 6
40,50 10
63 16




蒸氣火鍋 近排咁hit,齋食都要百幾二百蚊,今次呢間餐廳,兩個鐘內俾你任食燒肉、日式料理,仲送多個海鮮蒸氣火鍋,平日$178就有交易,哇!玩勻3樣嘢,兩個鐘夠唔夠時間食呢?立即去片!



Be sure to Google: HEALTH HAZARDS LINKED TO UTILITY METERS. By Steve Elwart. 12-2012. The electric company put a “smart meter” on my bedroom wall! I didn’t even know it was there, but mine and my husband’s health started to suffer horrifically. Then I saw the meter and put the puzzle pieces together. I even bought a radiation meter. It’s a constant bath of radiation, as if I put my computer in bed with us. Then it sends out powerful “microwave” signals as well! Like cooking your brain and body. We bought an analog and changed it back. Get info and analog meter here: