11 Years Factory Moulded case circuit breaker-FTM2-DC Supply to Malawi

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Always customer-oriented, and it's our ultimate target to be not only the most reliable, trustable and honest supplier, but also the partner for our customers for 11 Years Factory Moulded case circuit breaker-FTM2-DC Supply to Malawi, We are glad that we are steadily growing with the active and long term support of our satisfied customers !


FTM2DC001

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




http://GembaAcademy.com — This is the first video of Gemba Academy’s course focused on using 3P (Production Preparation Process) in relation to Healthcare Facility Design. To learn more about this full course and other Lean related courses please visit http://gembaacademy.com.



http://ultrasoundinspections.com
Nashville Home Inspector writes: ARC Fault Breakers are required in most jurisdictions to be installed in the electrical panel that control the power to all receptacles, lights and even the smoke detector in all rooms that are considered a bedroom. Their function is to sense an arc in a connection or appliance causing them to trip preventing a possible house fire. They should be tested annually and replaced if found defective.
If you are in need of good detailed home inspection in the Middle Tennessee area or have questions about the inspection process, please contact Ultra Sound Home Inspections. We have been protecting buyers like you in the Middle Tennessee area since 2004 and will help you avoid buying the “money pit”. We will take the necessary time needed to explain each issue found so you will have a better understanding of any possible expenses that may be involved in correcting your new home.
Within a few hours of the inspection you will be provided a comprehensive computer generated report from our 600 item home inspection check list with digital photos that clearly addresses all of the issues we discussed and that were found.
Don’t wait, visit our website today and schedule online or give us a call. We’ll give you the peace of mind you deserve.
Ultra Sound Home Inspections
615-476-1967

Related Products

WhatsApp Online Chat !