Overview:
Our primary goal is to offer our clients a serious and responsible business relationship, providing personalized attention to all of them for 12 Years Factory Moulded case circuit breaker-FTM2-DC to Morocco Manufacturers, welcomes all overseas friends and merchants to establish collaboration with us. We will provide you with honest, high quality and efficient service to meet your requirements.
Frame size Inm(A): | 160 | 250 | 400 | 630 | |||||
Rated current (A): | 20,25,32,40,50,63,80,100,125,160, | 160,180,200,225,250 | 250,315,350,400 | 400,500,630 | |||||
Poles: | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | |
Rated voltage (V) AC: | DC250,DC500,DC750,DC1000 | ||||||||
Rated insulationvoltage(V): | 1000 | 1000 | 1000 | 1000 | |||||
Rated impulse withstand voltage Uimp(KV): |
800 | 800 | 800 | 800 | |||||
Breaking Capacity: | S | S | S | S | |||||
Ultimate short-circuit capacity Icu (KA) | DC250V: | 30 | / | 30 | / | 30 | / | 30 | / |
DC500V: | 25 | / | 25 | / | 25 | / | 25 | / | |
DC750V: | 15 | 15 | 15 | 20 | 15 | 20 | 15 | 20 | |
DC1000V: | / | 10 | / | 10 | / | 10 | / | 10 | |
Service short-circuit capacity Ics (KA) |
DC250V: | 75%Icu | / | 75%Icu | / | 75%Icu | / | 75%Icu | / |
DC500V: | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | |
DC750V: | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | 75%Icu | |
DC1000V: | / | 75%Icu | / | 75%Icu | / | 75%Icu | / | 75%Icu | |
operating performance | Electrical life: | 3000 | 3000 | 1000 | 1000 | ||||
Mechanical life: | 10000 | 10000 | 5000 | 5000 | |||||
Arcing distance(mm) | No more than 50 | No more than 50 | No more than 50 | No more than 50 | |||||
Class | A | ||||||||
L(mm) | 155 | 165 | 257 | 275 | |||||
W(mm) | 90 | 120 | 105 | 140 | 140 | 184 | 210 | 280 | |
H1(mm) | 68.5 | 69.5 | 95 | 95 | |||||
H(mm) | 100 | 105 | 154 | 154 |
To purchase, visit:http://www.swgr.com/store/circuit-breakers/molded-case/product/TQD22225WL,22-19212.aspx
Stock # 22-19212, GENERAL ELECTRIC, Circuit Breaker, Catalog No. TQD22225WL, Frame Amps 225, Trip Amps 225, 2 Poles, 240 Volts,
Reconditioned Circuit Breakers
The TQD22225WL Circuit Breaker has been reconditioned per MIDWEST’s rigorous service procedures based on 30 years experience. The TQD22225WL circuit breaker has been maintained and refurbished per industry standards and per MIDWEST’s Quality Control Program (QCP). The services include applicable internal and external procedures, repairs, and replacement of deficient components. In addition to standard electrical tests, MIDWEST also performs live function tests on the TQD22225WL. These services far exceed the routine reconditioning of the TQD22225WL performed by many circuit breaker vendors and resellers. MIDWEST certifies the TQD22225WL circuit breaker has passed our QCP before shipping.
New Surplus Circuit Breakers
A “New Surplus” Circuit Breaker is a circuit breaker that has never been installed, but is not “New from the Factory” or “New from the Manufacturer or Distributor” of the TQD22225WL circuit breaker. It may be referred to as New in the Box, New Surplus, Never Installed, Never Energized, or other such term that avoids the label “New from the Manufacturer.” A New Surplus TQD22225WL circuit breaker should not be considered new from the manufacturer or manufacturer’s Distributor. Surplus and New Surplus TQD22225WL circuit breakers must pass MIDWEST’s (QCP) Quality Control Program.
MIDWEST Electrical Testing & Maintenance Co., Inc.
5141 North 35th Street, Milwaukee, WI 53209