13 Years manufacturer Miniature circuit breaker-FTB3LE for Amsterdam Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Gaining customer satisfaction is our company's aim forever. We will make great efforts to develop new and top-quality products, meet your special requirements and provide you with pre-sale, on-sale and after-sale services for 13 Years manufacturer Miniature circuit breaker-FTB3LE for Amsterdam Factory, "Passion, Honesty, Sound service, Keen cooperation and Development" are our goals. We are here expecting friends all over the world!


Product illustration:

FTB3LE

Technical Data

Model FTB3LE Residual current circuit-breaker
Number of poles IP+N,2P,3P,3P+N,4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) CD 6, 10, 16, 20, 25, 32, 40, 50, 636,10,16,20,25,32,40

Rated residual operating current(mA)

AC A 3030,50

Rated residual non-operating current(mA)

ACA 1515,25
Residual current breaking time 30mA≦0.1s  250mA≦0.04s
Rated short-circuit breaking capacity (KA) 40~63A6~32A 1012
Rated residual current breaking capacity(KA) 4.5
Mechanical & electrical life: 20,000 operations
Installation  
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm²,reversibility of connections
Tightening torque 2 Nm
Ambient temperature (°C) -5°C ~ +40°C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 80 490 610 710 820

Exterior and dimensions

FTB3LE11

Number of poles width(mm) Modules
1 / 2 54 3
2 / 2 72 4
3 / 3 100 5.5
3 / 4 112.5 6.25
4 / 4 130.5 7.25




PESSOAL É O SEGUINTE,ESSE IDR TRAZ A PROTEÇÃO CASO A PESSOA ESTEJA DESCALÇA OU EM CONTATO COM UMA PAREDE SEM ISOLAMENTO NO CORPO,MAS SE ELA ESTIVER CALÇADA E PEGAR POR EXEMPLO EM UM FIO FASE E UM NEUTRO,O CHOQUE É INEVITÁVEL.
VEJA EFEITOS DO CHOQUE ELÉTRICO:
O IDR evita que a pessoa leve um choque maior que 30mA, mas não evita um choque menor.

Efeitos fisiológicos da corrente elétrica (pessoas c/ no mínimo 50kg de peso):

500mA = parada cardíaca
30mA = RISCO de fibrilação cardíaca irreversível
10mA = nenhum efeito perigoso se houver interrupção em no máximo 5 segundos
0,5mA = ligeira contração muscular
0,1mA = sensação de formigamento

Resumindo: O IDR não evita o choque, mas evita que alguém saia com sequelas!

OBS.: em nenhum momento o disjuntor desarmou com a fuga de corrente, pois ele só desliga se houver uma sobrecarga ou um curto-circuito. Isso mostra a necessidade de ter o IDR para completar a proteção; O IDR não desarma se alguém tomar um choque pegando na fase+neutro ou fase1+fase2, pois isso é um consumo normal para o IDR. Ele somente desarma se houver fuga de corrente à terra!