14 Years Factory wholesale Miniature circuit breaker-FTB2LE to Somalia Importers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We stick to our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We aim to create more value for our customers with our rich resources, advanced machinery, experienced workers and excellent services for 14 Years Factory wholesale Miniature circuit breaker-FTB2LE to Somalia Importers, We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!


Product illustration:

ftb2le

 Technical Data

Model FTB2LE Miniature circuit-breaker
Number of poles IP+N,2P,3P,3P+N,4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated residual operating current(mA) AC A 30

30,50,100

Rated residual non-operating current(mA) AC

A

15

15,25,50

Residual current breaking time 30mA≦0.1s  250mA≦0.04s
Max. breaking time(s) 0.1
Rated short-circuit breaking capacity(KA) 6.5
Rated residual current breaking capacity(KA) 4.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation  
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm²,reversibility of connections
Tightening torque 2 Nm
Ambient temperature (°C) - 5°C ~ +40°C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 340 420 530 630 710

 

Exterior and dimensions

gggggg

Number of poles Width(mm) Modules
1 / 2 54 3
2 / 2 72 4
3 / 3 100 5.5
3 / 4 112.5 6.25
4 / 4 130.5 7.25

 

 

 





Circuit breaker finder with GFCI. The circuit breaker finder pinpoints the specific breaker powering the circuit being worked on. Eliminates guessing and unwanted power outages caused by tripping the wrong breaker. The transmitter sends locator signal through outlet wiring. For use on energized circuits. The GFCI test verifies operation of GFCI protected outlets. A LED light gives visual confirmation of the presence of live voltage on outlet. A receiver pinpoints the breaker receiving the signal from the transmitter. A green LED illuminates when correct breaker is located.