15 Years Manufacturer Moulded case circuit breaker-FTM2-DC to Nairobi Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for 15 Years Manufacturer Moulded case circuit breaker-FTM2-DC to Nairobi Manufacturers, If you are interested in any of our items, please don't hesitate to contact us and take the first step to build up a successful business relationship.


<

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




  • To purchase, visit:http://www.swgr.com/store/circuit-breakers/molded-case/product/F2050,22-9939.aspx

    Stock # 22-9939, WESTINGHOUSE, Circuit Breaker, Catalog No. F2050, Frame Amps 100, Trip Amps 50, 2 Poles, 600 Volts

    Reconditioned Circuit Breakers

    The F2050 Circuit Breaker has been reconditioned per MIDWEST’s rigorous service procedures based on 30 years experience. The F2050 circuit breaker has been maintained and refurbished per industry standards and per MIDWEST’s Quality Control Program (QCP). The services include applicable internal and external procedures, repairs, and replacement of deficient components. In addition to standard electrical tests, MIDWEST also performs live function tests on the F2050. These services far exceed the routine reconditioning of the F2050 performed by many circuit breaker vendors and resellers. MIDWEST certifies the F2050 circuit breaker has passed our QCP before shipping.

    New Surplus Circuit Breakers

    A “New Surplus” Circuit Breaker is a circuit breaker that has never been installed, but is not “New from the Factory” or “New from the Manufacturer or Distributor” of the F2050 circuit breaker. It may be referred to as New in the Box, New Surplus, Never Installed, Never Energized, or other such term that avoids the label “New from the Manufacturer.” A New Surplus F2050 circuit breaker should not be considered new from the manufacturer or manufacturer’s Distributor. Surplus and New Surplus F2050 circuit breakers must pass MIDWEST’s (QCP) Quality Control Program.

    MIDWEST Electrical Testing & Maintenance Co., Inc.
    5141 North 35th Street, Milwaukee, WI 53209



    We break the tie, and hate that koopa guy.