FTM2DC001

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




here i demonstrate a faulty RCD, then i take it apart and look at what parts are inside an RCD. interesting. pretty much what i thought would be inside. enjoy. NOTE: PLEASE DON’T LEAVE UNPLEASANT COMMENTS TELLING ME THAT I DID SOMETHING WRONG WITH THIS VID. IF YOU DON’T LIKE IT, GO AND WATCH A FLUFFY BUNNY BUNNY VID INSTEAD! I’M SICK OF HAVING TO DELETE NASTY COMMENTS!
RCD’S SHOULD TRIP EVERY TIME THE TEST BUTTON IS PUSHED, IF THEY FAIL TO TRIP CALL A LICENSED ELECTRICAL CONTRACTOR AND HAVE IT LOOKED AT. THIS RCD FAILED TO TRIP THE FIRST TIME THE TEST BUTTON WAS PRESSED AND STARTED TO TRIP MORE OFTEN AFTER I PLAYED WITH THE RCD A BIT, INCASE I’M NOT BEING CLEAR: POST YOUR OWN CONTENT INSTEAD OF BAGGING MINE!



Product Description:

Supplied with Cutler Hammer HFD3030L type, 30 Amp, 3 Pole, Molded Case Circuit Breaker.