18 Years Factory offer Miniature circuit breaker-FTM8 for Israel Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

With our rich experience and considerate services, we have been recognized as a reliable supplier for many international buyers for 18 Years Factory offer Miniature circuit breaker-FTM8 for Israel Factory, We warmly welcome you to establish cooperation and create a bright future together with us


aaad

Technical Data

Model
FTM8 Miniature circuit-breaker
Number of poles
IP 2P 3P 4P
Rated frequency:
AC 50/60Hz
Rated voltage (V) AC
230/400
 Rated current (A)
C
6, 10, 16, 20, 25, 32, 40, 50, 63
D
6, 10, 16, 20, 25, 32, 40, 50, 63
Rated breaking capacity(KA)
4.5(6~40A),  6(50~63A)
Mechanical & electrical life:
10,000 operations
protection rating
IP20
Installation
On DIN rail 35mm according to JB6525
Connection capacity:
Cross-section of conductors up to 25mm2
Tightening torque
2 Nm
Ambient temperature (C)
-5C ~ +40C
Altitude (m)
≤2000m
Relative air humidity
no more than 95%
pollution degree
installation condition
Used in place without obvious shock and vibration
Weight (g)
106
212
308
426

Tripping Characteristic

aad

Exterior And Dimensions

ssaa

Number of poles
b
e
1P
72
66
2P    3P     4P
75
69

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A)

Nominal cross section area of copper wire(mm²)

1~6

1

10

1.5

16,20

2.5

25

4

32

6

40,50

10

63

16





How to Find the Fuse Box or Circuit Breaker Box 00:00:47 Part 1 Finding Your Circuit Breaker or Fuse Box 00:00:55 1 – Search inside 00:01:40 2 – Search …



http://www.ctelectrical.com/ (203) 723-9052

CT Electrical Services is the leading provider for your Generac Generator, Electrical ,and Solar PV System needs serving
Connecticut residents.

0:05 Hi, this is Bruce Angeloszek from CT Electrical Services. I’m going to show you how to check your oil, and when to.

0:10 It’s important to check your oil every 200 hours, or two years. Whichever one occurs first.

0:14 The first step is to turn off your breaker if its in the running position, and your power is off from the utility.

0:24 The Next step is to turn the machine off manually, by hitting the off controller.

0:30 This is where the dipstick is located on the machine.

0:42 If you have to check your oil. First you want to take off the front cover by pulling up and out.

0:48 Locate the oil fill, and spin the cap off.

0:51 You want to use genuine Generac motor oil 5w30.

0:56 To start the machine. Press the auto button on the controller.

1:01 Once the machine is warm after 30 seconds, open the lid and turn on the main breaker. You now have power back to your house.