Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" and the theory of "quality the basic, trust the first and management the advanced" for 18 Years Factory Surge protective devices-SPD for America Factories, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.


Poduct Illustration

bb

Product Features

- The Surge protective devices(SPDs), suitable for residential,commercial and industrial appications, are designed to limit transient overvoltage and run-off lightning currents.

- It provides reliable protection from the destructive effects of lightning and switching

overvoltages.

Function:

- are lightning current arrsters, they can handle and divert high energy from lightning.

-they are necessary when the installation is exposed to direct lightning(for example when the buiding is equipped with external lightning protection system or powered by aerial lines).

Technical Data

Model: Max continuous operationl voltage Uc-(V): Nominal discharge current In(8/20s)(KA): Max. discharge current Imax(8/20μs)(KA): Level of protection Up(KV): Protection category:
FTY-D25 385 10 25 1.5      D
275 10 25 1.2
FTY-D25/NPE 385/255 10 25 1.5/1.2      D
275/255 10 25 1.2
FTY-C40 420 20 40 2      C
385 20 40 1.8
275 20 40 1.5
FTY-C40/NPE 420/255 20 40 2.0/1.5      C
385/255 20 40 1.8/1.5
275/255 20 40 1.5
FTY-B60 420 30 60 2.2 B
385 30 60 2
FTY-B60/NPE      420/255 30 60 2.2/1.5 B
385/255 30 60 2.2/1.5
FTY-80 420 40 80 2.5 B
385 40 80 2.2
FTY-B80/NPE 420/255 40 80   2.5/1.5 B
385/255 40 80   2.5/1.5
FTY-B100 440 50 100 3 B
420 50 100 2.8
FTY-B100/NPE 440/225 50 100 3.0/1.5 B
440/226 50 100 3.0/1.5
  Model Max. continuous operationl voltage Uc-(V) Impulse current Limp(10/ 350MS) Nominal discharge current (8/20MS)  Voltage protection level Follow current interruting rating Ifi  Max. back-up fuse  Response time Stocking and operating temperature
FTY-125 275V/50/60Hz 25KV 20KA ≤1.8KA 17.5KArms 125AgL ≤100ns -40℃-+70℃

 

 





Presenter: Maxime Berger, B.Eng., M.A.Sc. Systems Integration, Bombardier Transportation, Americas Division

Overview:
1. General Presentation:
a. Overview on Rail Passenger Train DC Power Systems.
b. Why EMTP?
c. Models:
- DC Primary Power (600 V to 1.5 kV): Substation, Rails, Circuit Breaker, and Fuse.
- DC Auxiliary System (37.5 V to 110 V): Battery, Converter, Circuit Breaker, Fuse, Loads, and Overvoltage Protection Devices.
d. Examples of Case Study:
- Transient Overcurrent Protection (Primary Power).
- Overcurrent Protection.
- Overvoltage Protection.
- Battery Sizing according to IEEE Std 1568.

2. Demo: Complete Overcurrent Protection Example in EMTP.



সিলিং ফ্যান কানেকশন কিভাবে করা তা আমি এই ভিডিওতে দেখিয়েছি,ভিডিওটি ভাললাগলে অন্যজনকে দেখার জন্য শেয়ার করুন ও নতুনি নতুন ভিডিও পেতে চ্যানেলটি সাবস্ক্রাইব করুন ,ধন্যবাদ সবাইকে Ceiling fan connection

Related Products

WhatsApp Online Chat !