Model: FTB10
Pole: 1P+N
Rated current (A): 6,10,16,20,25,32,40
Rated frequency: 50
Rated voltage (V): 230
Rated impulse withstand voltage Uimp(KV): 4
Breaking Capacity: 6
Operating cycle times /hour 240
Power on 4500
Power off 10000
Conventional non-tripping current: 1.13In t≤1h
Conventionaltripping current: 1.45In t<1h
2.55In 1s<t<60
Instantaneous tripping type: C
Instantaneous non-tripping current: t≤0.1s 5In
Instantaneous tripping current: t<0.1s 10In
Connection Wire ㎜²: Min/Max 1/10
Size(L×W×G)mm 1P+N 74.2×18×80




To purchase, visit: http://www.swgr.com/store/circuit-breakers/molded-case/product/CHH3100,22-10424.aspx

Stock # 22-10424, WESTINGHOUSE, Circuit Breaker, Catalog No. CHH3100, Frame Amps 225, Trip Amps 100, 3 Poles, 240 Volts,

Reconditioned Circuit Breakers

The CHH3100 Circuit Breaker has been reconditioned per MIDWEST’s rigorous service procedures based on 30 years experience. The CHH3100 circuit breaker has been maintained and refurbished per industry standards and per MIDWEST’s Quality Control Program (QCP). The services include applicable internal and external procedures, repairs, and replacement of deficient components. In addition to standard electrical tests, MIDWEST also performs live function tests on the CHH3100. These services far exceed the routine reconditioning of the CHH3100 performed by many circuit breaker vendors and resellers. MIDWEST certifies the CHH3100 circuit breaker has passed our QCP before shipping.

New Surplus Circuit Breakers

A “New Surplus” Circuit Breaker is a circuit breaker that has never been installed, but is not “New from the Factory” or “New from the Manufacturer or Distributor” of the CHH3100 circuit breaker. It may be referred to as New in the Box, New Surplus, Never Installed, Never Energized, or other such term that avoids the label “New from the Manufacturer.” A New Surplus CHH3100 circuit breaker should not be considered new from the manufacturer or manufacturer’s Distributor. Surplus and New Surplus CHH3100 circuit breakers must pass MIDWEST’s (QCP) Quality Control Program.

MIDWEST Electrical Testing & Maintenance Co., Inc.
5141 North 35th Street, Milwaukee, WI 53209

Related Products

WhatsApp Online Chat !