20 Years Factory XJM7 Measuring Box (Low Voltage Power Measurement Box) Export to Peru

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

In the past few years, our company absorbed and digested advanced technologies both at home and abroad. Meanwhile, our company staffs a team of experts devoted to the development of 20 Years Factory XJM7 Measuring Box (Low Voltage Power Measurement Box) Export to Peru, We welcome new and old customers to contact us by phone or send us inquiries by mail for future business relationships and achieving mutual success.


USE:

XJM7 series of lighting Power metering box is suitable in power centralized measurement management of apartment buildings office buildings. Pulse-type power meter can be installed  to according to the design needs to achieve computer management. Besides, proper location is preserved to install remote-measuring remote sensing equipment. There are small circuit breakers installed in the cabinet to protect the line from overload, short circuit. The power meter and circuit breaker rated current are selected by design.

In line with GB7251.1-1997 and 7251.3-1997 standards.

3C certificate:

XJM7 Measuring Box (Low Voltage Power Measu-2





I need help figuring out Ruud furnace error codes.

If all the lights are dead, the problem is the power or lack thereof. Check that the furnace is on, and if so, make sure the fuses aren’t blown or the breaker wasn’t tripped.

It has power. I know that because it tried to start up and now flashes an error code at me.

Ruud furnaces usually try to ignite three times before locking up.

What do I do if it isn’t igniting?

If the unit isn’t igniting, turn off the power and the gas. If it has a honeywell or white rogers valve, turn the knob clockwise to off, and if it is a robertshaw valve, turn the control lever to the off position.

A Nordyne is almost easier – they make the same furnace for everyone.

Not exactly the same – some Nordyne furnaces have only a red light, others red and green, a few with an amber light, depending on the name plate they put on top of it.

Then I can’t use the standard error codes for Nordyne’s furnaces to figure out the Ruud furnace’s blinking at me.

Ruud furnaces typically have a power light that doesn’t flicker unless the voltage wiring is messed up and an okay light that flickers when things are not okay.

So tell me what the blinking means.

One blink is a soft shut down.

And the first solution for a furnace this smart is the same as a gaming console – reboot it.

Two blinks means the pressure switch is stuck open when the inducer is on. You can try to manually close the switch and see if it works after that.

Or replace the switch, which is the cheapest option before paying someone to check the blowers and vents for problems so bad it interferes with the air pressure.

Three blinks means either the limit switch is open or the roll out control is engaged. Four flashes means the pressure switch is closed.

What do five flashes mean?

That means you blinked at the wrong time when it was flashing six times.

I don’t get it.

Most Ruud furnaces, like the more expensive Rheem furnaces that passed quality control, don’t use the five flash error code anymore.

What does the six flash error code mean?

Six flashes means the line and neutral are reversed.

Since I’m not rewiring the furnace in my spare time and it actually ran since installation, that means the grounding for the furnace is messed up.

Or the wiring is otherwise messed up, or the control board is on the fritz.

Then I’m back to rebooting before I give up and pay someone to replace the most expensive parts.



I went out and upgraded the saw to work on the 240v circuit I installed a few months back. I am not sure if it has more power I just got a new blade on it and was not gonna go ripping 2 x 4′s and all… I found there is an access panel in the back which just made life easier for finishing the saw table now.