2017 High quality DC miniature circuit breaker-FTBD for Jakarta Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

we can offer high quality products, competitive price and best customer service. Our destination is "You come here with difficulty and we give you a smile to take away" for 2017 High quality DC miniature circuit breaker-FTBD for Jakarta Manufacturers, items won certifications with the regional and international primary authorities .For far more detailed information,please contact us!


Product illustration:

ftbd

Technical Data

Model FTBD DC miniature circuit-breaker
Picture  
Number of poles IP 2P
Rated frequency: AC 50/60Hz
Rated voltage (V) 125/250 250/500
Rated current (A) 1,2,3,4
Rated ultimate short-circuit breaking capacity(KA) 6.5
Rated current (A) 6,10,16,20,25,32,40,50,63
Rated ultimate short-circuit breaking capacity(KA) 20/10 20/10
Rated impulse withstand voltage Uimp(KV) 4
Mechanical and electrical life: 20000
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2, Cross-section of busbar from 0.8-2mm2
Ambient temperature (°C) -25°C ~ +45°
Altitude (m) ≦4000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 116 232

Tripping characteristic

ftbd-5

Exterior  and dimensions

ftbd-6342

Number  of poles 1P 2P
A 80±0.8
B 74.2±0.8 75.7±0.8
C

17.8±0.8

35.6±0.8

D 44±0.8
E

68.7±0.8

70.2±0.8

F 45±0.8
G 35.5±0.8




http://www.aaronequipment.com/usedequipment/generators/diesel-fuel-and-natural-gas-fuel/cummins-47394001

Used- Cummins 250 kW standby diesel generator set. Cummins LTA-10G1 engine rated 380 HP at 1800 RPM, SN-34844306. 3/60/277/480V. 400 Amp main-line circuit breaker. Coolant heater. Battery charger. Weather enclosure. 200 gallon sub-base fuel tank. 255 Hrs. Yr 1996. Passed load test 8/20/2015



Mark Elliott, owner of Yellow Hat Inspections in Plano, TX http://yellowhatinspections.com Introduction Utilizing patented technology, the SureTest® circuit analyzers “look behind walls” to identify wiring problems that can lead to personal shock hazards, electrical fires, or equipment performance issues. Personal shock hazards stem from poor grounding, false grounds, and/or no ground fault protection. Electrical fires are primarily caused by arc faults and high resistance points that lead to glowing connections in the circuit wiring. And, equipment performance issues arise due to insufficient voltage available under load, poor ground impedance, and high ground-to-neutral voltage. In fact, it’s estimated that 80% of power quality performance issues are related to the faulty wiring issues stated above. Product Features • True RMS • Measures voltage drop under 12, 15 and 20-amp loads • Measures voltage: Line, Ground-to-Neutral, Peak, Frequency • Measures Hot, Neutral and Ground conductor impedances • Identifies proper wiring in 3-wire receptacles • Identifies false (bootleg) grounds • Tests GFCIs for proper operation • Tests AFCIs for proper operation (61-165) • Checks for Shared Neutrals that lead to AFCI nuisance tripping (61-165) • Verifies dedicated circuits (with 61-176 adapter) • Includes 1-ft. extension cord and carrying case https://youtu.be/pjIEp47jRMA For more information about home inspection in the Dallas, Texas area, call Yellow Hat Inspections at 972-832-3460 http://www.idealind.com/products/test_measurement/circuit_analyzers/suretest61164video.jsp