2017 New Style Miniature Circuit Breaker FTB1 for Holland Importers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

"Based on domestic market and expand overseas business" is our development strategy for 2017 New Style Miniature Circuit Breaker FTB1 for Holland Importers, Inspired by the rapid developing market of the fast food and beverage consumables all over the world , We are looking forward to working with partners /clients to make success together .


Product illustration:

20170427170914

 

Accessories
 Auxiliary contact Auxiliary contact and alarm contact  Shunt release Shunt release and auxiliary contact  Under voltage release  Over voltage release  Busbar mounting base  Motor-driven operation
OF OF+SD MX MX+OF MQ MG MP CD

 

Product Features

Under normal condition, the working principle of main thermostic bimetal in FTB1 SMCB is the same to the usual circuit breakers, it is used for overload tripping. when there is a short-circuit on a branch circuit breaker, the magnet core in the main current path would tilt the moving contact away from the fixed contact to break the circuit,thus producing the electric arc, and limiting the short-circuit current effectively.

In the maintime,the short-circuit current flow to the supplementary current path, a selective resistor and a selective bimetal are connected in series of the supplementary curret path, limiting the short-circuit current to a few hundred amps.

When the downstream circuit-breaker has tripped because of a short-circuit, the contact tips reclose automatically through a simple spring-type system,ensuring other unaffected branch circuits continue in operation.If a short-circuit occur between the FTB1 and the downstream circuit-breaker, another bimetal release enables short-time delayed tripping,ensuring the contact tips remain in the open position enabling isolating.

a0170427173357

Scope of use

It is primarily used in critical installations,for instance, office buiding, laboratory, theatre, museum, hotel, shopping mall, telecommunication, coal mine and shipping, chemical industry and metallurgy, industrial plants,medical and health care, bank and securities exchange,airport, underground express way, military establishment and similar loads that requires non-interrupted and reliable power supply.

Technical Data

Model FTB1-100
Number of poles  ada
Rated frequency: AC 50(60)Hz
Rated voltage (V) AC 230/400
Rated current (A) 20, 25, 32, 40, 50, 63,80,100
Breaking capacity  Icn/Ics(KA) LH 15/7.525/12.5
Rated impulse withstand voltage (kV) 6
Tripping characteristic E
Electric arc distance(mm) ≤35
Mechanical life 10,000
Insulation function yes
Installation  
Pollution degree
Ambient temperature (°C) -5°C ~ +40°C
Altitude (m) Not higher than 2000m
Installation Mounted on DIN rail, busbar adaptor or by screw terminal
Connection capacity: Connection to cables,busbars or terminals
Weight (g) 313      617       932       1241

 

 Trippping behavior

 

Test Tripping characteristic Conventional non-tripping current Conventional tripping current Initial status Tripping time
a b E E 1.05In 1.2In Cold statusRight after test 1 ≧2h﹤2h
Test Tripping characteristic Delayed tripping current short-time delayed tripping current Initial status Tripping time
c E 5In   Cold status 0.05s<t<5s(In≦32A)   0.05s<t<10s(In>32A)
d E   6.25In Cold status 0.01s﹤t﹤0.3s

Coordination table

The FTB1 series operates selectively with respect to the combination with MCBs

MCB(B,C characteristic) FTB1(Characteristic E)
In A 20 25 32 40 50 63 80 100
10 T T T T T T T T
16 T T T T T T T
20 T T T T T T
25 T T T T T
32 T T T T
40 T T T
50 T T
63 T

Note: T represents total selectivity

Applications

170428111611

Tripping characteristic

adfa (3)

Exterior and dimensions

adfa (4)





Electrical Wiring Irvine CA, Call (949) 566-8335 Palmer Electrical Systems

If you don’t know the difference between the black wire and white wire or don’t know what a ground wire is for, and you need help with your electrical wiring we can help.

Whether you need to replace a cable or conductors the electrical code is there for your protection and all electrical installations whether an electrical wire or insulated conductors should comply with the national electrical code. Wiring safety codes need to be followed if you are just replacing a switch or need a whole new system.

If the time of replacing electrical wiring has come. And your electric wiring has timed out, as it only has a limited lifespan. For the record, electric wiring PVC cables have an estimated lifespan of twenty years. By the time twenty years have passed, homeowners are advised to replace their electrical wiring as precautionary measures for the purpose of maintaining a safe home.

The condition of cables and wires deteriorates over time. If they are used continuously, lives are being recklessly exposed and properties endangered. This is why regular replacement schedules should be followed. Naturally, a licensed electrical technician or electrical engineer can perfectly replace the electrical wiring at home. A licensed electrical technician can determine whether the wirings are no longer safe to use and if so, he can make the necessary replacements.

Electric wirings are not only to be replaced at the end of their expected lifespans. When electric problems occur, electrical wiring should be replaced right away. To better identify electric problems, one should know first what a consumer unit is and the switches that go along with it. Basically, the consumer unit is responsible for electrical distribution in the panels installed at home. The panels are put together and enclosed. The miniature circuit breakers, or MCBs, are utilized to protect home appliances from electric fault and overheating of cables. When MCBs are switched off or tipped off, the electric supply to the affected circuit is cut off. This usually happens as the result of short circuit, earth-fault, or overload. If electric fault causes too much damage, the replacement of electrical wiring is necessary.

Fixing the air conditioner is another issue that may require replacing electrical wiring. There are two kinds of air conditioning systems. There is the window-type and there is the split-type. The window-type requires an electric plug for the power source. And, in order to mount it, a boxy rectangular hole-in-the-wall is necessary. On the other hand, the split-type is more complicated to install since its features are more sophisticated. The main two units of split-type units are the internal unit, where the cold air is blown, and the external unit, where the compressor is located. The two units are linked through the pipes to make the air conditioner cold, but the two units need two corresponding power sources. Frequent check-ups and cleaning of the plastic filters are the two simple ways of preventing the problem. If this is done, there is a small chance of experiencing electric failures.

Replacing electrical wiring is a serious and risky task. If you know the principles of wire replacement, you can save yourself from electric burns and other fatal injuries. This is a situation where being careful is of vital importance. Replacing electric wiring requires that you turn off the power to the circuits and then double check whether it is really switched off. And if you managed to successfully replace everything, such as the electrical receptacles, you need to use testers to know whether the receptacle is already working. Simple steps like these will help keep you and those who visit your home safe. Replacing electrical wiring can be a manageable task if done carefully. And if you are still in doubt of your own capabilities, it is a smart decision to hire a professional electrical technician.

Please share this video: https://youtu.be/6fXyIpN9vAI

http://ezinearticles.com/?Learning-About-the-Common-Electrical-Wiring-Questions&id=3153181

Related Products

WhatsApp Online Chat !