Adhering to the principle of "quality, service, efficiency and growth", we have gained trusts and praises from domestic and international client for 21 Years Factory Moulded case circuit breaker-FTM2-DC to Czech republic Manufacturer, Please send us your specifications and requirements, or feel free to contact us with any questions or inquiries that you may have.


FTM2DC001

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




Hear how to maximise Switchboard Space using RCBo’s (Residual current Circuit Breaker with Overload protection) from Keean at Electrical Unity.

With EDA you can increase your profit by:

QUOTING LESS – to help you win the job
PAY LESS – to keep costs down
MAKE MORE – money $$$$

Both you and your customers will be happy; Freecall – 1300 66 88 91

Shop online at http://edaonline.com.au or visit us at 20 Smith Street, Port Melbourne, 3207 Victoria.



The LM1851 and RV4141 datasheets at the end are only included as rough examples of what the circuit in the breaker looks like. I would have used the datasheet for the device in the breaker, but it does not have a recognizable part number. It is also a SIP device, and all of the GFCI controllers that Digi-Key sells are in DIPs or SOs, so package style got me nowhere WRT identifying the device.
I do not recommend doing this to anything that will actually be used and claim no liability for any injuries, deaths, property damage or rips in the space time continuum (however serious) that happen as a result of doing so.

Related Products

WhatsApp Online Chat !