We enjoy a very good reputation among our customers for our excellent product quality, competitive price and the best service for 8 Year Exporter Miniature circuit breaker-FTBD to Chile Factories, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!


Protection rating: IP20
Installation: On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², 
Ambient temperature (°C): Cross-section of conductors up to 25mm²,
Altitude (m): ≦4000m
Relative air humidity: no more than 95%
Pollution degree:
Installation condition: Used in place without obvious shock and vibration
Weight (g): 116 /232




Designed for installing electrical contractors, this exciting video features the new range of MCCB Panelboards and MCCB devices from Wylex. This two part video is instructional and informative, giving an overview of the range, features and benefits for the installer, as well as showing how the equivalent of a bespoke factory built assembly, complete with incoming and outgoing metering and integral surge protection can be easily assembled on site by the installer themselves.

Wylex is delighted to announce this introduction of a new range of MCCB panel-boards and devices to complement its existing range of MCB distribution boards and consumer units. This extensive circuit protection product range offers the installer a one-stop shop for industrial commercial and residential, circuit protection systems.

Further information is available from Electrium Sales Tel: 01543 455000 or by visiting www.electrium.co.uk.



http://www.solardave.com/index.php/what-type-of-electrical-panels-are-not-good-for-solar-video/
What types of electrical panels are good candidates for solar? And what are bad candidates for solar? Is a
question I asked John Shaw project engineer for
Bella Energy.

John Shaw: Long story short there are panels out
there through grand father clause, if any
contractor came in and did any type of electrical
work, that electrical work could not pass because
of the fact that there is a panel there for a
particular brand because of law suits and stuff like
that, but that is a bit too nit picky.

The things I look for when doing a site visit are
100 amp main service limit the size of the back
feed breaker that we use to feed the house there are other ways
to integrate a system into the house with line
side taps which can be done in a couple of
different locations.

We are looking for 150 plus amp service with empty breaker spaces at least two that is going to be the best scenario. We can certainly get around
anything and everything we run into but it is a
question of how much addition time and weather or not we are service
upgrade or we might need to ask Xcel for a service
upgrade or stuff like that.

The easiest way to integrate a system into your
home which is what is called a backfeed service
breaker onto your service
panel some people call a breaker box. If there are
a couple of empty spaces we take a special breaker
instead of drawing power and sending it to your
living room actually takes power from the PV system and
puts it on to the bus bar which then is just
another source of electrons on those bus bars for all of the other
breakers to pull from.

But we are limited in the size of the breaker we can put in there, by the overall service. So for example lets say
you have 100 amp service, the biggest breaker we
can use to back feed the system is 20 amp breaker?

That would mean that you could only do about a 2.5 to 3 kilo watt system.

If I am not mistaken.

3 sounds about right I would have to do the math
to figure it out,
I dont have it in my head there are some other
ways to get around it too. What the code actually
says is that if it is a 100 service that usually
means you have a 100 amp bus bar in your service
panel and 100 amp main disconnect that means you can
only feed the bus bar with 120% of its rating, so it is feed by the main breaker usually
100 percent of its main rating you can have 20%
but if the main breaker happens to be an 80 amp
breaker on a 100 amp bus bar
that is another 40 amps you could add or
you could sometimes change out that main breaker
but it is easier to go to a line side tap then
involving to changing out main breakers but you
know there are many ways you can do it.