8 Year Exporter Moulded case circuit breaker-FTM2-DC to Gabon Importers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for 8 Year Exporter Moulded case circuit breaker-FTM2-DC to Gabon Importers, Looking to the future, a long way to go, constantly striving to become the all staff with full enthusiasm, one hundred times the confidence and put our company built a beautiful environment, advanced products, quality first-class modern enterprise and work hard!


FTM2DC001

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




Distribution networks are facing unprecedented challenges. Increases in demand, distributed generation, use of electric vehicles and heat pumps all require a new methodology of network management and control. The Kelvatek Low Voltage active network management system provides the monitoring, communications and control functions to help utilities create an LV network for the future.

WEEZAP is an LV vacuum circuit breaker combined with advanced measurement and protection capability. The compact retrofit design allows WEEZAP to be fitted directly to existing LV panels in replacement of the fuse. It is not necessary to replace the LV board itself. Fitting is simple and fast with a minimum of training.

The VCB design allows the WEEZAP to close and open the circuit at the LV substation either locally or remotely. The WEEZAP can protect the network by opening the circuit breaker in overload and fault conditions. Configuration settings allow local automated re-closing; alternatively reclose control can be via the Network Management System (NMS).



I mount the electric box and the circuit breaker panel onto the phase converter, and the error counter gets ignored.

Related Products

WhatsApp Online Chat !