8 Years Manufacturer Miniature circuit breaker-FTB2GLE for Canada Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for 8 Years Manufacturer Miniature circuit breaker-FTB2GLE for Canada Factory, We look forward to supplying you with our products in the near future, and you will find our quotation is very reasonable and the quality of our products is very excellent!


Model: FTB2GLE
Pole: 1P+N,2P,3P,3P+N,4P
Rated voltage (V): Type C, Type D
rated residual operating current Type AC 30
rated residual non-operating current Type AC 15
Rated breaking Capacity(KA): 6
Rated residual connection and breaking Capacity(KA): 4.5
Mechanical and electrical life(times): 20000
Residual current tripping type: Electronic
Connection type: 1-25mm²
Function: short-circuit protection,overload protection,leakage protection,Isolation
Ambient Temperature( ℃): -5 - +40
Altitude(m): ≤2000m
Pollution degree: 2
Protection degree: IP20
Size(L ×W ×H)mm 1P+N 72.5×54×90
2P 72.5×72×90
3P 72.5×100×90
3P+N 72.5×112.5×90
4P 72.5×130.5×90




http://www.eibmarkt.com/de/products/HAGER-FI-LS-Schalter-1P-N-10kA-B-16A-10mA-ACA516D.html
HAGER FI/LS-Schalter 1P+N 10kA B-16A 10mA ACA516D
FI/LS-Schalter 1P+N 10kA B-16A 10mA ACA516D Polzahl (gesamt) 2, Anzahl der abgesicherten Pole 1, Bemessungsspannung 230V, Bemessungsstrom 16A, Bemessungsfehlerstrom 0,01A, Fehlerstrom-Typ A, Energiebegrenzungsklasse 3, Bemessungsschaltvermögen nach EN 60898 10kA, Frequenz 50 Hz, Auslösecharakteristik B, Mitschaltender Neutralleiter, Breite in Teilungseinheiten 2, Einbautiefe 68mm, Schutzart (IP) IP20, FI/LS-Schalter nach DIN EN 61009-1, VDE 0664-20, pulsstromsensitiv und stoßstromfest bis 250 A, Kurzschlussfestigkeit 10 kA bei Vorsicherung 63 A / gL, Berührungsschutz nach VDE 0106 Teil 100, Einzelentnahme aus dem Phasenschienenverbund, Beschriftungsfeld

http://www.eibmarkt.com/en/products/HAGER-Earth-leakage-circuit-breaker-B16-0-01A-ACA516D.html

HAGER Earth leakage circuit breaker B16/0,01A – ACA516D
Earth leakage circuit breaker B16/0,01A Number of poles (total) 2, Number of protected poles 1, Rated voltage 230V, Rated current 16A, Rated fault current 0,01A, Leakage current type A, Current limiting class 3, Rated short-circuit breaking capacity EN 60898 10kA, Frequency 50 Hz, Release characteristic B, Concurrently switching N-neutral, Width in number of modular spacings 2, Built-in depth 68mm, Degree of protection (IP) IP20,

EAN: 3250611067719
FI-Leitungsschutzschalter, FI/LS, FI/LS-Kombination, FI/LS-Kombischalter, FI/LS-Schalter, Fehlerstrom-Leitungsschutzschalter, Fehlerstrom-Schutzeinrichtung, Personenschutzautomat



The circuit breaker on my Lionel ZW transformer can be slow to trip under short circuit and overload conditions. In this video I show how I improved the safety of my ZW transformer by installing supplemental sub circuit circuit breakers. I show testing that selects the breakers with the best ratings for this role.

Related Products

WhatsApp Online Chat !