Big Discount Miniature circuit breaker-FTB3 to Leicester Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We aim to find out quality disfigurement from the production and supply the best service to domestic and overseas customers wholeheartedly for Big Discount Miniature circuit breaker-FTB3 to Leicester Factory, we have built a reliable reputation among many customers. Quality&customer first are always our constant pursuit. We spare no efforts to make better products. Look forward to long-term cooperation and mutual benefits!


Product illustration:

ftb3

Product Features

- A breaking capacity of 12kA up to 32A and 10kA between 40 to 63A.

- Current-limiting scheme: in the event of a short circuit, are able to limit the let-through current to 60%-70% of the rated current.

- The trip mechanism ensures perfect closure every time,thereby considerably improving the performance of these devices and extending their average lifetime.

-The arc extinguishing system: allows the short-circuit currents of very high value to be interrupted extremely rapidly, the remarkable opening speed of contacts opening and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time, ensuring reliable protection of short-circuit.

- The internal contact position allows an exact information of the circuit-breaker status: “green”,open contacts;“red”,closed contacts,independently of the toggle position.

- Sealing/locking sealable with 1 mm wire, to prevent unwanted tripping.

- The supply lines of the protected circuit can be connected to either the upper or lower terminals of the circuit-breakers(reversibility of connections).

- The double terminal of these circuit-breakers enables simultaneous connection of cables and busbars.

Technical Data

213123

Breaking capacity(KA) 40-63A 10
6-32A 12
Mechanical and electrical life: 20,000 operation
Protection rating IP20
Installation On symmetrical DIN rail 35mm /Panel Mounting
Connection capacity: Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm², reversibility of connections
Ambient temperature (°C) -5°C ~ +40°C
Altitude (m) not higher than 2000m
Relative air humidity no more than 95%
Pollution degree
Weight (g) 116 234 352 472

Tripping characteristic

112121

Exterior and dimensions

11111

Unit(mm)

 

Number of poles

1P 2P 3P 4P
a 80±0.8
b 74.2±0.8 75.7±0.8
c 17.8±0.5 35.6±0.8 53.4±0.8 71.2±0.8
d 44±0.8
e 68.7±0.8 70.2±0.8
f 45±0.8
g 35.5±0.8

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A) Nominal cross section area of copper wire(mm²)
1~6 1
10 1.5
16,20 2.5
25 4
32 6
40,50 10
63 16




Here you will see a very good temperature controlled triac circuit which can be used for attic fans(Like I made it for), heaters, as well as motors and other electrical loads. Circuit shown in the video is rated 10 Amps/120V. The circuit can be modified for use with 240v if needed. This circuit is intended for people who have experience working with “high voltage” circuits. Safety comes first. If you have any questions, please post them in the comment section.

Thanks For watching!

Link to Schematic:

**HELP SUPPORT THIS CHANNEL by posting links to my videos on other websites and blogs, rating a thumbs up, SUBSCRIBING, and watching my video playlists.**



Fallout New Vegas Dead Money 3 Circuit Breaker Electric Box Fuse Locations Mixed Signals Quest

http://www.claytonkills.com

╔═╦╗╔╦╗╔═╦═╦╦╦╦╗╔═╗
║╚╣║║║╚╣╚╣╔╣╔╣║╚╣═╣
╠╗║╚╝║║╠╗║╚╣║║║║║═╣
╚═╩══╩═╩═╩═╩╝╚╩═╩═╝

Related Products

WhatsApp Online Chat !