Cheapest Price Miniature circuit breaker-FTB10LE for Auckland Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for Cheapest Price Miniature circuit breaker-FTB10LE for Auckland Manufacturers, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more detail


 

Model:   FTB10LE
Poles: 1P+N
Rated current (A): 6,10,16,20,25,32,40
Rated frequency(Hz): 50
Rated operational voltage(V): 230
Breaking Capacity:Ics(KA) 4.5
Rated residual operating current:A/AC: 30
Breaking time:A/AC: 15
Breaking Time ms : I△=I△n ≤100
I△=5I△n ≤40
Mechanical and electrical life: 10000
Conventional non-tripping current:   t≤1h
Conventional tripping current: t≤1h
1s<60s
 Instantaneous tripping types: C
 Instantaneous non-tripping current: 5In
 Instantaneous tripping current: 10In
Connecting Wire: 1/25
Size(L×W×H)mm:   74.2×36×80




This video shows what happens when multi-core cables attached to cable ladder using cable ties only and subjected to short circuit cable fault.
Depending on fault levels cable cleats should be used to secure cables and to provide short circuit protection against disastrous cable faults, this includes the cable cleating of multi-core power cables.

T&D distribute Ellis Patents cable cleats providing safety critical support to vital cable circuits. Cable cleats must withstand peak short circuit forces generated by the actual cable installation – Ellis Patents 3rd party certified cable cleats provide peace of mind containment of low and high voltage cables.

Ellis Patents are global leaders in the innovation and manufacture of nylon, aluminium and stainless steel cable cleats – EP satisfy the operational requirements of the construction, oil, gas, rail, utilities, wind energy and power generation industries.

Vital Short Circuit Protection with Ellis Patents Cable Cleats

Ellis Patents are a leading voice in the campaign to have cable cleats reclassified as short-circuit protection devices. A move that would mean cable cleats would be placed on a parallel with fuses and circuit breakers. “This reclassification makes absolute sense. In the event of a cable fault, the forces between cables reach their peak in the first quarter cycle, which is the point that cable cleats earn their crust. In contrast, circuit breakers typically interrupt the fault after 3 or even 5 cycles by which time, if the cable cleats are underspecified, the cables will no longer be secure, but will be putting vital electrical installations and lives at unnecessary risk,” says Paul Nolan UK Sales Manager, EP.

Thorne & Derrick UK (tel 0191 4901547) are national distributors and worldwide exporters of LV-HV Cable Installation, Cable Jointing & Electrical Equipment – we service UK and global businesses involved in cable installations, cable jointing, substation and electrical construction at LV, 11kV, 33kV and EHV. T&D service utilities, power, construction, rail, mining, offshore, oil, gas, petrochemical and hazardous area industries.
For more products please visit www.cablejoints.co.uk

Ellis Patents Cable Cleats : http://www.cablejoints.co.uk/sub-product-details/cable-cleats-stainless-steel-cable-cleats-emperor-vulcan-atlas-varicleat



Introduction

Related Products

WhatsApp Online Chat !