China Factory for XJM7-J Measuring box (Infrastructure Energy Measurement Box) to Stuttgart Factory

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We are committed to providing easy,time-saving and money-saving one-stop purchasing service of consumer for China Factory for XJM7-J Measuring box (Infrastructure Energy Measurement Box) to Stuttgart Factory, For further information, please do not hesitate to contact us. All inquiries from you will be highly appreciated.


USE:

XJM7-J metering box (infrastructure power metering box) is suitable in power supply system with AC 50HZ, rated voltage 380 / 220V , as the power measurement in construction site.

 

Meet GB7251.1-1997 and GB7251.3-1997 standards.

3C certificate:

XJM7-J Mgy Measurement Box)-2





AC Clamp Meter Uni-T UT202A http://toolboom.com/en/Digital-Clamp-Meter-UNI-T-UT202A.php
AC/DC Clamp Meter Uni-T UT203 http://toolboom.com/en/Digital-Clamp-Meter-UNI-T-UT203.php
First let’s find out what is clamp meter. It is a meter device capable of measuring current in a non-contact way. That is a main advantage of a clamp meter compared to traditional amperemeters or multimeters. You don’t need to break the circuit to conduct measurements – you may actually conduct measurements of the line under voltage, as well as measuring high currents. Operation safety is one more advantage – you may measure current of the insulated conductor.
Measuring current with these meters is simple. You should switch to the required current measurement range (in our case it is 600 Amperes), press the trigger to open the jaws, and place the conductor under test inside and close the jaws. The display will show the measurement results.
The main element of a clamp meter is currents sensor. There are two types of sensors used: a current transformer or a Hall sensor. Depending on the sensor used the meter may measure either alternate current, or direct and alternate current.
So, the clamp meter with a current transformer:
In this meter, under this plastic lid, there is a magnetic core. If you open the jaws you may see parts of it. The role of a primary winding is played by the conductor that measures current, and the secondary winding is placed under the platic lid, we can not see it.
The main advantage of such kind of design is a rather low price and simplicity. The drawback is that it is a transformer, so you may measure alternate currents only.
Another type of design is a clamp meter with a Hall sensor. There is no magnetic core, if you open the jaws you may notice that. The advantage is that the Hall sensor is sensitive to both alternate and direct currents. And the disavantage is a higher price.
So, let’s start with alternate current measurements. The main condition for measuring current is that you have to clench exactly the conductor that you need to measure. Like this. So if we clench both wides at a time or the wole cable, we will get a zero result beacause the meter will detect the difference between the currents. As both these conductors carry the same current – the difference will be a zero. So if you have a cable consisting of several wires and you need to measure each of them, you don’t need to strip it like we have here, you just need to find a place where the cable is divided into separate wires, for example somewhere in the electric cabinet, and than start measuring.
And the second important condiition is setting the correct measurement range. If you are not sure about what is the current of the network, you have to start with the maximum range.
I will demonstrate this. Now I’ll measure the current used to power the electric kettle. Let’s imagine I don’t know what current is used, but it has to be lower than 600 Amperes. I turn the kettle on and switch the meter to alternate current measurements within 600 Amperes range. Now I clench the wire. The kettle uses some current about 7 Amperes. I switch to a lower range – 200 Amperes, I get 7.6 Amperes. And to measure the current with the best accuracy I switch to 20 Ampere range – the meter shows 7.73 Amperes. If I clench both wires I’ll get something about zero. You have to follow the rule of clenching one certain conductor.
Now I take the meter with a Hall sensor – the measurement procedure is similar. One difference is that you have to set the readings to zero before starting the new measurement, as the Hall sensor is magnetic sensitive. So I zero the display readings and measure – we’ve got a current slightly less than 8 Amperes.
Now I will use UT203 Clamp Meter to measure current in real-time conditions un a three-phase circuit.
And now I’m demonstrating the direct current measurements. We have a power supply unit providing 3 Ampere current in the circuit. I switch the meter to 40 Ampere range. As the Hall sensor is very sensitive we need to zero the display readings. And now we measure the conductor – it shows 3.15 Amperes. The absolute accuracy is about 150-170 milliAmpere, but it is not much taking into account that our measuring range is 40 A. AC clamp meter can not measure DC current at all.
These two models, as most of the modern clamp meters, apart from current, are capable of measuring AC/DC voltage, resistance, they have a continuity buzzer and diode test functions. These are fully functional multimeters with a non-contact current measurement function. I recommend you to watch the video “How to Use a Multimeter” where you may find a detailed demonstartion of these functions.
In this review I tried to answer the main questions that appear while using digital clamp meters. Thank you for attention and take care!



MPMC Powertech Corp equip the test room with system meets the international standard, high-performance integrated test system. The test system use Lab VIEW, powerful analytical tools, combined with the American NI company ‘S NI high-speed data acquisition card to achieve the real-time measurement, analysis and monitoring on various parameters and performance of the generator set. In constant temperature of 40 degrees Celsius and ultra-quiet testing room, to meet the maximum 2500KW generator set testing needs. With different loads, can be done at any percentage of sudden load, sudden offload, and are able to display and save information of changes in form or graph, recovery time and curve in the loading.
MPMC’s test system has the following characteristics:
(1) The superior handling, quickly generate test reports, automatically determines the test results.
(2) Flexible scalability facilitates future station position, power expansion, and can achieve multiple machines in parallel.
(3)powerful function, real-time monitoring function offer the real-time operational data of generator set; the huge amount of data storage can support more than one million models of generator sets data saving. Besides, break the restrictions of traditional instruments, solve the problems of harmonic test and vibration test, optimize the test system and provide a more professional platform for the detection of generator sets.
(4) High efficiency, a single test system can test completed more than one hundred units per day, reached the international advanced level.
(5) Meet a variety of stringent standards, such as GJB235A-97 standard “military exchange mobile station General technical conditions” GJB 1488-92: “Common test methods for military internal combustion engine power plant”.
Every generator set of MPMC must through this test. The test steps are as follows:
(1) Generator set is placed into the appropriate location of the test room, to allow sufficient space for air intake and exhaust.
(2)The external inlet connected to the engine fuel return pipe. Add oil to the engine pan, add coolant to the water tank.
(3)The load lines are connected to the output of the circuit breaker.
(4)Outside the test room, start the intake and exhaust fan and then start the generator set.
(5)In the control room operate the monitoring platform, reduce and increase loading, test each performance parameter, and automatically produce and analysis test report.
(6)If the product is qualified, gradually unload the entire load, let the generator run at idle load for 3 to 5minutes.After that, stop and drain the lubricant and coolant.
(7) The generators transported to the specified location, waiting for clearance and packing.
Mpmc Diesel Generator:http://www.mpmc-china.com

Related Products

WhatsApp Online Chat !