With our leading technology as well as our spirit of innovation,mutual cooperation, benefits and development, we will build a prosperous future together with your esteemed company for Factory best selling Miniature circuit breaker-FTM8 for Brazil Manufacturer, We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.


aaad

Technical Data

Model
FTM8 Miniature circuit-breaker
Number of poles
IP 2P 3P 4P
Rated frequency:
AC 50/60Hz
Rated voltage (V) AC
230/400
 Rated current (A)
C
6, 10, 16, 20, 25, 32, 40, 50, 63
D
6, 10, 16, 20, 25, 32, 40, 50, 63
Rated breaking capacity(KA)
4.5(6~40A),  6(50~63A)
Mechanical & electrical life:
10,000 operations
protection rating
IP20
Installation
On DIN rail 35mm according to JB6525
Connection capacity:
Cross-section of conductors up to 25mm2
Tightening torque
2 Nm
Ambient temperature (C)
-5C ~ +40C
Altitude (m)
≤2000m
Relative air humidity
no more than 95%
pollution degree
installation condition
Used in place without obvious shock and vibration
Weight (g)
106
212
308
426

Tripping Characteristic

aad

Exterior And Dimensions

ssaa

Number of poles
b
e
1P
72
66
2P    3P     4P
75
69

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A)

Nominal cross section area of copper wire(mm²)

1~6

1

10

1.5

16,20

2.5

25

4

32

6

40,50

10

63

16





Electrical Outlets- December and January are the most dangerous months for electrical fires. Fire deaths are highest in winter months, which call for more indoor activities, and increases in lighting, heating, and appliance use. The bedroom is the leading area of fire origin for residential building electrical fires. However, electrical fires that begin in the living room/family room/den areas result in the most deaths.

Outlets deteriorate from repeated use, from plugging-in and unplugging appliances as is often done in kitchens and bathrooms. As a result, when plugs fit loosely into receptacles, especially the two-prong ungrounded type, they may slip partially or completely out of the receptacle with only slight movement of the attached cord. Receptacles in this condition may overheat and pose a serious fire hazard; if covered by a curtain or drape, the fire hazard is even greater.

To Learn More about Electrical Outlets in your Home or Office as well as Other Electrical Services we Provide, Click on the Link below!

http://www.safewayelectricco.com/electricaloutlets.html

For Immediate Assistance Call Today! We are Open 24 Hours 7 Days a Week!
We Service: Los Angeles County, Orange County, Riverside County and San Bernardino County
1-800-496-4311Safe-Way Electric Solar Co is available 24/7 we are licensed, insured and bonded. License #809692. Corporate Office 909-464-9983. www.safewayelectricco.com . For quick electrical service call the following number nearest you…909- 383-4782….562-941-5170….951-461-4213…714-894-7219…626-968-2700 949-494-4915 Call Toll Free 800-496-4311.



http://www.brainshark.com/geis/vu?pi=zGZz18JjTBz7HTIz0 – Review of UL testing and National Electrical Code marking and application requirements

Related Products

WhatsApp Online Chat !