We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for Factory directly provide Miniature circuit breaker-FTB2LE for Latvia Manufacturers, we are seeking for extensive cooperation with honest customers, achieving a new cause of glory with customers and strategic partners.
Product illustration:
Technical Data
Model | FTB2LE Miniature circuit-breaker | |
Number of poles | IP+N,2P,3P,3P+N,4P | |
Rated frequency: | AC 50/60Hz | |
Rated voltage (V) AC | 230/400 | |
Rated current (A) | C
D |
6, 10, 16, 20, 25, 32, 40, 50, 63
6,10,16,20,25,32,40 |
Rated residual operating current(mA) | AC A | 30
30,50,100 |
Rated residual non-operating current(mA) | AC
A |
15
15,25,50 |
Residual current breaking time | 30mA≦0.1s 250mA≦0.04s | |
Max. breaking time(s) | 0.1 | |
Rated short-circuit breaking capacity(KA) | 6.5 | |
Rated residual current breaking capacity(KA) | 4.5 | |
Mechanical & electrical life: | 20,000 operations | |
Protection rating | IP20 | |
Installation | ||
Installation | On DIN rail 35mm according to JB6525 | |
Connection capacity: | Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm²,reversibility of connections | |
Tightening torque | 2 Nm | |
Ambient temperature (°C) | - 5°C ~ +40°C | |
Altitude (m) | ≤2000m | |
Relative air humidity | no more than 95% | |
Pollution degree | Ⅱ | |
Installation condition | Used in place without obvious shock and vibration | |
Weight (g) | 340 420 530 630 710 |
Exterior and dimensions
Number of poles | Width(mm) | Modules |
1 / 2 | 54 | 3 |
2 / 2 | 72 | 4 |
3 / 3 | 100 | 5.5 |
3 / 4 | 112.5 | 6.25 |
4 / 4 | 130.5 | 7.25 |
–
Derek Cole is the General Manager of One Hour Heating & Air Conditioning®, an independently owned and operated franchise based in Laurinburg, North Carolina since 1953. He has more than 15 years of experience in the HVAC industry and has created two You Tube broadcasts, The Comfort Experts and #AskDerekCole, filled with tips and tricks on saving energy and being comfortable. He was named the Top 40 under 40 in the HVAC industry by the News magazine and featured in Entrepreneur Magazine Franchise Player Spotlight. Derek has also been seen on CBS, FOX, NBC, ABC, and Bloomberg Business sharing about One Hour Heating & Air Conditioning®.
Find Derek here:
One Hour Heating & Air: http://www.onehouraircarolinas.com
Facebook: http://facebook.com/derek.cole.779
Twitter: http://twitter.com/derekmcole
Instagram: http://instagram.com/derekmcole
Medium: http://medium.com/@derekmcole
Snapchat: https://www.snapchat.com/add/derekmcole
Federal Pacific Panel are the Most Dangerous Panels you can have. Thier Breakers have been known to fail to trip and they are responsible for 1000′s of House Fires. If you own a home and have one of these panels DO NOT WAIT till there is a problem. Call a Certified Professional Electrician and have them come out and replace this panel.