Factory made hot-sale Miniature circuit breaker-FTB3LE to Curacao Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We always think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body and the living for Factory made hot-sale Miniature circuit breaker-FTB3LE to Curacao Manufacturers, We, with great passion and faithfulness, are willing to provide you with perfect services and striding forward with you to create a bright future.


Product illustration:

FTB3LE

Technical Data

Model FTB3LE Residual current circuit-breaker
Number of poles IP+N,2P,3P,3P+N,4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) CD 6, 10, 16, 20, 25, 32, 40, 50, 636,10,16,20,25,32,40

Rated residual operating current(mA)

AC A 3030,50

Rated residual non-operating current(mA)

ACA 1515,25
Residual current breaking time 30mA≦0.1s  250mA≦0.04s
Rated short-circuit breaking capacity (KA) 40~63A6~32A 1012
Rated residual current breaking capacity(KA) 4.5
Mechanical & electrical life: 20,000 operations
Installation  
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm²,reversibility of connections
Tightening torque 2 Nm
Ambient temperature (°C) -5°C ~ +40°C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 80 490 610 710 820

Exterior and dimensions

FTB3LE11

Number of poles width(mm) Modules
1 / 2 54 3
2 / 2 72 4
3 / 3 100 5.5
3 / 4 112.5 6.25
4 / 4 130.5 7.25




Relay vs Circuit Breaker- Difference between Relay and Circuit Breaker

The difference between the Relay and Circuit breaker is explained on the various factors like the principle of their operation, working of relay and circuit breaker, type of device they are, voltage, their usability and whether it works as an amplifier or not.

In this video we will go to learn Difference between Relay and Circuit Breaker.

more videos:-

MCCB vs MCB│ Difference between MCCB and MCB│

ELCB vs RCCB │ Difference Between ELCB and RCCB│

Thanks for watching this video. Don’t forget like share and comments. More update please subscribe our channel learning Engineering.

https://www.youtube.com/channel/UC6qf8AGvAGixZXWdxapvCqw

content source by-

http://circuitglobe.com/difference-between-relay-and-circuit-breaker.html



a transformer at the new york power authority explodes in a massive fire ball on march 3, 2012 in massena new york. the explosion is shown here on video.
An explosion at the New York Power Authority’s St. Lawrence-FDR Power Project sent a fireball into the air Saturday afternoon.

NYPA Regional Manager Rick Turner said a “catastrophic failure” involving a circuit breaker at a switch yard caused the fire shortly after 2 p.m. Saturday. There were no injuries resulting from the explosion, Mr. Turner said.

“Some of the oil in the breaker ignited when the explosion occurred,” Mr. Turner said.

NYPA immediately contacted the New York State Department of Environmental Conservation. The circuit breaker did not seep oil into the river, he said. There was some release of oil on land, which has since been contained.

“There’s been no release in the St. Lawrence River we’re aware of,” he said.

He said the breaker was a “total loss.” It failed in the proper way, he said.

“When the breaker fails, this is the mode it fails in,” he said.

NYPA officials are still trying to determine a cause for the failure. Saturday’s high winds may have played a role, Mr. Turner said.

Representatives from the St. Regis Mohawk Reservation who had expressed concerns about the explosion will be touring the facility on Thursday, Mr. Turner said.

NYPA had issued no statements about the explosion on Monday, Tuesday or Wednesday. But shortly before 7 p.m. Wednesday an email, purporting itself to be sent by “Rick Turner,” was sent to several media representatives providing some information about the incident. The email address was sent from “Rickturnershouldbefired@gmail.com.”

“On March 2nd, an oil filled circuit breaker exploded, sending burning oil in a 1/4 mile radius. No one was injured,” the email states.

The email claimed oil entered the river, an allegation NYPA strongly denies.

“RM Rick Turner is to blame for this oil entering the St. Lawrence River,” the email states.

The message then links to what appears to be a one-minute long surveillance video of the power project. About halfway through, a ball of smoke and fire is seen shooting up into the air within close proximity to the water.

The email also provides Mr. Turner’s contact information, including his cell phone, office phone and email, and directs readers to contact him.

Mr. Turner, responding to the message Wednesday night, said the email purporting itself to be from “Rick Turner” was not from him.

“That would be very odd, for Rick Turner who is regional manager, to send out an email,” he said.

He has no idea where the email originated fro, and declined to speculate on the sender’s intentions.

“I couldn’t begin to even guess. I have no idea whatsoever,” Mr. Turner said. “We’ve got great employees. Everything is solid there.”

Mr. Turner was first hired by NYPA in 1981 and has held his current position since 2006.

Related Products

WhatsApp Online Chat !