Factory making Moulded case circuit breaker-FTM2X for Ecuador Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Our personnel are always in the spirit of "continuous improvement and excellence", and with the superior quality products, favorable price and good after-sales services, we try to win every customer's trust for Factory making Moulded case circuit breaker-FTM2X for Ecuador Manufacturers, we have built a reliable reputation among many customers. Quality&customer first are always our constant pursuit. We spare no efforts to make better products. Look forward to long-term cooperation and mutual benefits!


FTM2X--010202

Model: FTM2X-63
Frame size rated current Inm(A): 63
Poles: 3,4
Rated current(A): 10,16,20,25,32,40,50,63
Rated operational voltage(V): AC380V/400V AC480V/500V AC530V/550V AC660V/690V
Rated insulation voltage(V): AC1000
Rated impulse withstand voltage Uimp(KV): 8
Rated ultimate short - circuit breaking capacity(KV): AC380V/400V 35
Rated  short circuit breaking capacity 25
Rated ultimate short - circuit breaking capacity(KV): AC480V/500V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC530V/550V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC660V/690V 10
Rated  short circuit breaking capacity(KV): 7.5
Operating performance(KV):  Electrical life: 8000
Mechanical life: 20000
Tripping mode(KV): thermomagnetic
Protection category(KV): distribution protection
motor protection
Arcing distance(KV): not more than 50(0)
Isolating function(KV): A
Connection: Front connection plate,rear connection plate,plug-in rear connection plate
Isolating function Yes
Size: L (mm) 130
W(mm) 75/100
H(mm) 90




Part 2

Ryan’s new house was built in the 1920′s. The house was in excellent condition but it had a 60 amp electrical service that was installed in 1920 when the house was built. At the time four 15 amp circuits were considered to be more than enough. The circuits were run correctly for the time, but that meant there were no grounded circuits.
In 2014 four 15 amp circuits just aren’t enough. Modern kitchens with microwaves, toaster, mixers, blenders, coffeemakers, and all the other appliances require a minimum of two 20 amp circuits. TV’s computers, stereo systems and lighting means each room needs at least a seperate 20 amp circuit. Then if you add a dryer, range, central air conditioning, and the 60 amp service is just way to small
Ryan decided he wanted to install a new service. To bring his house up to the 21st century he planned to install a 200 amp grounded circuit breaker panel with room for 40 circuits. To get rid of the overhead wires attached near the roofline he wanted an underground feed.
With the estimated cost running at approximately $2500.00 he called on Old Sneelock to help with a DIY installation. End cost approximately $800.00 for permits, materials, inspections, and connecting to the service provider.
This video shows the installation and connections for the main 3/0 copper cables in the power panel



My website: http://kaizerpowerelectronics.dk/electronics/mysterious-failure-of-a-siemens-mini-circuit-breaker-c6a-5sy41/

From one day to another this mini circuit breaker stopped working, I had been using it wrongly as a on/off switch and was wondering if there was a mechanism inside to disable it after too many on/off switches, as MCBs are only rated for a finite number of operations.