factory Outlets for Miniature Circuit Breaker FTB2-63 for Belize Factories

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We enjoy a very good reputation among our customers for our excellent product quality, competitive price and the best service for factory Outlets for Miniature Circuit Breaker FTB2-63 for Belize Factories, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more detail


Product illustration

gagwq

Technical Data

Model FTB2-63 Miniature circuit-breaker
Number of poles IP 2P 3P 4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

1,2,3,4, 6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated breaking capacity(KA) 6.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2 , Cross-section of busbar from 0.8- 2mm2,reversibility of connections
Tightening torque 2 Nm
Ambient temperature ( C) -5 C ~ +40 C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 102 208 308 408

Product Feature

- These circuit breakers are intended for the protection of circuits against overloads and short circuits in residential, commercial and industrial premises;

- It covers the rating range from 6 to 63A with a uniform breaking capacity of 6.5 kA throughout;

- Current-limiting scheme: in the event of a short circuit, are able to limit the let-through current to 60%-70%  of the rated current;

- The arc extinguishing system: allows the short-circuit currents of very high value to be interrupted extremely rapidly, the remarkable opening speed of contacts opening and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time;

-The sensitivity and reliability of the trip mechanism ensures perfect closure every time,thereby considerably improving the performance of these devices and extending their average lifetime;

- The internal contact position allows an exact information of the circuit-breaker status:“green”, open contacts;“red”, closed contacts,independently of the toggle position;

- Sealing/locking sealable with 1 mm wire , to prevent unwanted  tripping;

- The supply lines of the protected circuit can be connected to either the upper or lower terminals of the circuit-breakers(reversibility of connections). The double terminal of these circuit-breakers enables simultaneous connection of cables and busbars.

 

Tripping characteristic

qrgadg qweq

Exterior and dimensions

agg

Unit(mm)

Number of poles 1P 2P 3P 4P
a 80±0.8
b 74.2±0.8 75.7±0.8
c 17.8±0.5 35.6±0.8 53.4±0.8 71.2±0.8
d 44±0.8
e 68.7±0.8 70.2±0.8
f 45±0.8
g 35.5±0.8

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A) Nominal cross section area of copper wire(mm2 )
1~6 1
10 1.5
16,20 2.5
25 4
32 6
40,50 10
63 16




problem job i have been back 4 times on this one , runs good for a week then trips out at night .



Testing UPA-6.
The circuit breaker tester UPA-6 produced load in conjunction with the current transformer 10000/5А, connected with four 1-metre long current leads with a cross-section of 110 mm². Current on the transformer was measured with a comparator. Current adjustment was done with the voltage transformer RNO-80. Voltage on the voltage transformer RNO was measured with a voltmeter, current was measured with a clamp.
We set 6 kA, compared with the readings of reference measuring instruments and allowed 1 minute for the overheating protection to be activated.

http://www.kep.ua/en/device/10/upa-6/