Factory Outlets Surge protective devices-SPD for Croatia Manufacturers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Factory Outlets Surge protective devices-SPD for Croatia Manufacturers, We encourage you to make contact as we are looking for partners in our venture. We are sure you will find doing business with us not only fruitful but also profitable. We are ready to serve you with what you require.


Poduct Illustration

bb

Product Features

- The Surge protective devices(SPDs), suitable for residential,commercial and industrial appications, are designed to limit transient overvoltage and run-off lightning currents.

- It provides reliable protection from the destructive effects of lightning and switching

overvoltages.

Function:

- are lightning current arrsters, they can handle and divert high energy from lightning.

-they are necessary when the installation is exposed to direct lightning(for example when the buiding is equipped with external lightning protection system or powered by aerial lines).

Technical Data

Model: Max continuous operationl voltage Uc-(V): Nominal discharge current In(8/20s)(KA): Max. discharge current Imax(8/20μs)(KA): Level of protection Up(KV): Protection category:
FTY-D25 385 10 25 1.5      D
275 10 25 1.2
FTY-D25/NPE 385/255 10 25 1.5/1.2      D
275/255 10 25 1.2
FTY-C40 420 20 40 2      C
385 20 40 1.8
275 20 40 1.5
FTY-C40/NPE 420/255 20 40 2.0/1.5      C
385/255 20 40 1.8/1.5
275/255 20 40 1.5
FTY-B60 420 30 60 2.2 B
385 30 60 2
FTY-B60/NPE      420/255 30 60 2.2/1.5 B
385/255 30 60 2.2/1.5
FTY-80 420 40 80 2.5 B
385 40 80 2.2
FTY-B80/NPE 420/255 40 80   2.5/1.5 B
385/255 40 80   2.5/1.5
FTY-B100 440 50 100 3 B
420 50 100 2.8
FTY-B100/NPE 440/225 50 100 3.0/1.5 B
440/226 50 100 3.0/1.5
  Model Max. continuous operationl voltage Uc-(V) Impulse current Limp(10/ 350MS) Nominal discharge current (8/20MS)  Voltage protection level Follow current interruting rating Ifi  Max. back-up fuse  Response time Stocking and operating temperature
FTY-125 275V/50/60Hz 25KV 20KA ≤1.8KA 17.5KArms 125AgL ≤100ns -40℃-+70℃

 

 






I have owned this electric mower by Greenworks for about eight to nine months. It recently broke down and would not start. It resets the breaker every time I try to get it to turn on. So I found some vids on youtube on some possibilities and one guy hit it on the nail with the rectifier. In this video I talk about doing this repair in hopes that it could help someone else out there with the same problem.

If you are going to do this repair, you might as well add some thermal paste. See my video on adding thermal paste here :

Model number of rectifier is KBPC2504

https://www.amazon.com/gp/product/B0002KRDPI/ref=as_li_tl?ie=UTF8&camp=1789&creative=9325&creativeASIN=B0002KRDPI&linkCode=as2&tag=miggy05-20&linkId=664072f5de272b18ba034f2d9878ab2b

Greenworks 20 inch corded mower

https://www.amazon.com/gp/product/B002ZVOLXE/ref=as_li_tl?ie=UTF8&camp=1789&creative=9325&creativeASIN=B002ZVOLXE&linkCode=as2&tag=miggy05-20&linkId=d047c7affe14cd2e35027bbd0a210b8a

AmazonBasics Outdoor Extension Cord 50 feet 16 gauge

https://www.amazon.com/gp/product/B00OS7ETIA/ref=as_li_tl?ie=UTF8&camp=1789&creative=9325&creativeASIN=B00OS7ETIA&linkCode=as2&tag=miggy05-20&linkId=de76a167c0dc7503cf44d92b14def51f

Coleman Cable 02409 14/3 SJTW Vinyl Outdoor Extension Cord, Red, 100-Foot 14 gauge

https://www.amazon.com/gp/product/B00004SQEX/ref=as_li_tl?ie=UTF8&camp=1789&creative=9325&creativeASIN=B00004SQEX&linkCode=as2&tag=miggy05-20&linkId=347c15a873abf38f66437ed04222b66e

Related Products

WhatsApp Online Chat !