We have a highly efficient team to deal with inquiries from customers. Our goal is "100% customer satisfaction by our product quality, price & our team service" and enjoy a good reputation among clients. With many factories, we can provide a wide range of Factory Promotional Moulded case circuit breaker-FTM2X Supply to Surabaya, We believe that a passionate, innovative and well-trained team will be able to establish good and mutually beneficial business relationships with you soon. Please feel free to contact us for more details.


FTM2X--010202

Model: FTM2X-63
Frame size rated current Inm(A): 63
Poles: 3,4
Rated current(A): 10,16,20,25,32,40,50,63
Rated operational voltage(V): AC380V/400V AC480V/500V AC530V/550V AC660V/690V
Rated insulation voltage(V): AC1000
Rated impulse withstand voltage Uimp(KV): 8
Rated ultimate short - circuit breaking capacity(KV): AC380V/400V 35
Rated  short circuit breaking capacity 25
Rated ultimate short - circuit breaking capacity(KV): AC480V/500V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC530V/550V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC660V/690V 10
Rated  short circuit breaking capacity(KV): 7.5
Operating performance(KV):  Electrical life: 8000
Mechanical life: 20000
Tripping mode(KV): thermomagnetic
Protection category(KV): distribution protection
motor protection
Arcing distance(KV): not more than 50(0)
Isolating function(KV): A
Connection: Front connection plate,rear connection plate,plug-in rear connection plate
Isolating function Yes
Size: L (mm) 130
W(mm) 75/100
H(mm) 90




http://www.aaronequipment.com/usedequipment/generators/diesel-fuel-and-natural-gas-fuel/edi-46920001

Used- Energy Dynamics 400 kW standby diesel generator set model EDI-400-V. Volvo model TAD1242GE engine rated 602 HP at 1800 RPM, SN-8688378841. 3/60/277/480V. 600 Amp main-line circuit breaker. Coolant heater. Battery charger. Sound attenuated enclosure. 126 hrs. Year 2002. Passed load test 6/11/2015

Patrick Paden
Aaron Equipment Company
Direct: (630) 238-7539
Cell: (630) 258-6238
ppaden@aaronequipment.com
www.aarongenerators.com



Arc died only because contacts melted away.
This is what will happen if you install AC breaker into DC circuit, for example PV circuit.
And don’t try this at home kids. Well fuck it, do it. Better to test this in controlled environment than get a fucking fire in the fusebox.

http://mdiy.pl

Related Products

WhatsApp Online Chat !