We have the most advanced production equipment, experienced and qualified engineers and workers, recognized quality control systems and a friendly professional sales team pre/after-sales support for Factory source manufacturing Miniature Circuit Breaker FTB2-63 for Slovenia Manufacturers, We welcome new and old customers to contact us by phone or send us inquiries by mail for future business relationships and achieving mutual success.


Product illustration

gagwq

Technical Data

Model FTB2-63 Miniature circuit-breaker
Number of poles IP 2P 3P 4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

1,2,3,4, 6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated breaking capacity(KA) 6.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2 , Cross-section of busbar from 0.8- 2mm2,reversibility of connections
Tightening torque 2 Nm
Ambient temperature ( C) -5 C ~ +40 C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 102 208 308 408

Product Feature

- These circuit breakers are intended for the protection of circuits against overloads and short circuits in residential, commercial and industrial premises;

- It covers the rating range from 6 to 63A with a uniform breaking capacity of 6.5 kA throughout;

- Current-limiting scheme: in the event of a short circuit, are able to limit the let-through current to 60%-70%  of the rated current;

- The arc extinguishing system: allows the short-circuit currents of very high value to be interrupted extremely rapidly, the remarkable opening speed of contacts opening and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time;

-The sensitivity and reliability of the trip mechanism ensures perfect closure every time,thereby considerably improving the performance of these devices and extending their average lifetime;

- The internal contact position allows an exact information of the circuit-breaker status:“green”, open contacts;“red”, closed contacts,independently of the toggle position;

- Sealing/locking sealable with 1 mm wire , to prevent unwanted  tripping;

- The supply lines of the protected circuit can be connected to either the upper or lower terminals of the circuit-breakers(reversibility of connections). The double terminal of these circuit-breakers enables simultaneous connection of cables and busbars.

 

Tripping characteristic

qrgadg qweq

Exterior and dimensions

agg

Unit(mm)

Number of poles 1P 2P 3P 4P
a 80±0.8
b 74.2±0.8 75.7±0.8
c 17.8±0.5 35.6±0.8 53.4±0.8 71.2±0.8
d 44±0.8
e 68.7±0.8 70.2±0.8
f 45±0.8
g 35.5±0.8

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A) Nominal cross section area of copper wire(mm2 )
1~6 1
10 1.5
16,20 2.5
25 4
32 6
40,50 10
63 16




Relay vs Circuit Breaker- Difference between Relay and Circuit Breaker

The difference between the Relay and Circuit breaker is explained on the various factors like the principle of their operation, working of relay and circuit breaker, type of device they are, voltage, their usability and whether it works as an amplifier or not.

In this video we will go to learn Difference between Relay and Circuit Breaker.

more videos:-

MCCB vs MCB│ Difference between MCCB and MCB│

ELCB vs RCCB │ Difference Between ELCB and RCCB│

Thanks for watching this video. Don’t forget like share and comments. More update please subscribe our channel learning Engineering.

https://www.youtube.com/channel/UC6qf8AGvAGixZXWdxapvCqw

content source by-

http://circuitglobe.com/difference-between-relay-and-circuit-breaker.html



4 year old Trane air handler started making noise . sounds like a metallic clatter coming from the blower fan. spun the fan by hand and checked bearings for end play. tight , smooth and very quiet. noise starts when its powered up.it sounds like something is hitting the fan blades but everything is clear ! the fan never gets even close to 100% run. guess its about 60% .suspect control module but the noise is throwing me off. could this sound be caused by an electrical issue ? some one must have addressed this before ! going to pull the blower but as you can see there is no room. anyone recognize the problem ? it can save me a real headache . when i solve the problem it will be on the next video posted on this channel !

Related Products

WhatsApp Online Chat !