Factory wholesale Miniature circuit breaker-FTM8 for Sierra Leone Importers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

In the past few years, our company absorbed and digested advanced technologies both at home and abroad. Meanwhile, our company staffs a team of experts devoted to the development of Factory wholesale Miniature circuit breaker-FTM8 for Sierra Leone Importers, we are seeking for extensive cooperation with honest customers, achieving a new cause of glory with customers and strategic partners.


aaad

Technical Data

Model
FTM8 Miniature circuit-breaker
Number of poles
IP 2P 3P 4P
Rated frequency:
AC 50/60Hz
Rated voltage (V) AC
230/400
 Rated current (A)
C
6, 10, 16, 20, 25, 32, 40, 50, 63
D
6, 10, 16, 20, 25, 32, 40, 50, 63
Rated breaking capacity(KA)
4.5(6~40A),  6(50~63A)
Mechanical & electrical life:
10,000 operations
protection rating
IP20
Installation
On DIN rail 35mm according to JB6525
Connection capacity:
Cross-section of conductors up to 25mm2
Tightening torque
2 Nm
Ambient temperature (C)
-5C ~ +40C
Altitude (m)
≤2000m
Relative air humidity
no more than 95%
pollution degree
installation condition
Used in place without obvious shock and vibration
Weight (g)
106
212
308
426

Tripping Characteristic

aad

Exterior And Dimensions

ssaa

Number of poles
b
e
1P
72
66
2P    3P     4P
75
69

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A)

Nominal cross section area of copper wire(mm²)

1~6

1

10

1.5

16,20

2.5

25

4

32

6

40,50

10

63

16





To purchase, visit: http://www.swgr.com/store/circuit-breakers/molded-case/product/LXD63B500,22-8636.aspx

Stock # 22-8636, SIEMENS, Circuit Breaker, Catalog No. LXD63B500, Frame Amps 600, Trip Amps 500, 3 Poles, 600 Volts

TODAY, MIDWEST is the stand-alone leader in its field. MIDWEST combines highly trained, experienced, and dedicated personnel with state-of-the-art equipment and engineering procedures to provide our customers the successful services they need and deserve.

MIDWEST Electrical Testing & Maintenance Co., Inc.
5141 North 35th Street, Milwaukee, WI 53209



Why series motor cannot be started on no load || comprehensive viva questions and answers for eee-https://www.quora.com/Why-should-a-series-motor-never-be-started-on-no-load
Series motor cannot be started without load because of high starting torque. Series motor are used in Trains, Crane etc

-~-~~-~~~-~~-~-
Please watch: “Save Energy || Use Energy Saving Lamp”

-~-~~-~~~-~~-~-

Related Products

WhatsApp Online Chat !