Factory Wholesale PriceList for Automatic Transfer Switching Equipment-FTQ2E for Russia Importers

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Always customer-oriented, and it's our ultimate target to be not only the most reliable, trustable and honest supplier, but also the partner for our customers for Factory Wholesale PriceList for Automatic Transfer Switching Equipment-FTQ2E for Russia Importers, sincerely look forward to serving you in the near future. You are sincerely welcome to visit our company to talk business face to face with each other and establish long-term co-operation with us!


Body switch FTB2-63 MCB Series
Rated voltage (V): AC 400(4P/3P); AC 230V(2P)/50HZ
Rated insulation voltage: 440
Rated impulse withstand voltage Uimp(KV): 4
Rated breaking Capacity: 6.5
Mechanical and electrical life: electric 6000
Machinery 10000
Operating position: Normally on,backup on,Normal and backup off
Operating transfer time: ≤1.5
Electrical class: CB
Usage category: AC-33iB
Controller functions:
switch automaticly in condition of phase loss, pressure loss ,undervoltage and other power failure,
automatic change and automatic recovery ,automatic change and non automatic recovery,fire fighting
joint control, Manual/automatic adjustion,power/power on/tripping indication,fault alarm
Controller Operating Voltage: AC230V/50Hz
Undervoltage conversion value: AC175V(±5)
Undervoltage  return value: AC190V(±5)
Conversion Delay(normal to backup): 0S-60S adjustable,factory default setting:5S
Return Delay(normal to backup: 0S-60S adjustable,factory default setting:5S
Size(L×W×H)mm: 248 × 125×121




David Jones of Jones Air Conditioning & Electric explains in the video, How to…Using a Bonding Screw…AC Unit Repair

3920 Progress Ave Suite A5
Naples, Fl 34104
239-596-5855
www.jonesairconditioning.com



An earlier video showed my attempts to get the power to a kitchen wall back on, in that video I was unsuccessful. Today I finally got it to turn back on. Watch the last few seconds very carefully & you will see the spark that occurs every time the power comes back on (whether I am flipping the circuit breaker or it just comes back on on it’s own, as is sometimes does). This sparking is, I feel, a rather dangerous fire hazard. Especially as it will come back on all by itself. If the spark were to catch the paint or dry wall on fire when I am asleep or not home the result could be disastrous.