We keep improving and perfecting our products and service. At the same time, we work actively to do research and development for Good quality 100% Moulded case circuit breaker-FTM2-DC to kazakhstan Factory, We stick to providing integration solutions for customers and hope to build long-term, stable, sincere and mutual beneficial relationships with customers. We sincerely look forward to your visit.


FTM2DC001

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




EnerQuest’s Automatic Breaker Racking System, International Patent Pending, is the world’s first. Operators now have 100% control of the integral remote racking system for any low voltage circuit breaker from 70 amps to 3000 amps. The operator can stand outside of the ARC FLASH Boundary and rack a circuit breaker out to the disconnected position via HMI touch screen command or control room operator station.

The breaker has zero (0) incident energy while a safety lock is applied for lockout, tag out procedures. The operator can also rack the breaker back into the connected position. All of this alone while standing outside of the ARC FLASH Boundary.

The EnerQuest International Patent Pending system provides a wide range of modular configuration designs for above and below ground mining applications. The design provides for ease of installing, maintaining, operating and adapting to many mining needs while keeping Safety as a # 1 Priority. Some of the many operating features include:
• Remote Breaker Racking System
• Wireless Bus-joint Temperature Monitoring
• Integral Streaming Infra-Red Camera Reporting
• Remote Operation of all Switching Devices
• Live Line Voltage Indicators Local to Each Mining Plug Connector Location.