Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

We have our own sales team, design team, technical team, QC team and package team. We have strict quality control procedures for each process. Also, all of our workers are experienced in printing field for High Efficiency Factory Miniature circuit breaker-FTM8-LE for Saudi Arabia Factory, Our company warmly welcome friends from all over the world to visit, investigate and negotiate business.


Product illustration:

8-LE
Technical Data

Model FTM8LE Residual current circuit-breaker
Number of poles IP+N,2P,3P,3P+N,4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
 Rated current (A) C D 1,3,6,10,16,20,25,32,40,50,63 1,3,6,10,16,20,25,32,40,50,63
Rated residual operating current(mA) 30
Rated residual non-operating current(mA) 15
Residual current breaking time 30mA≦0.1s  250mA≦0.04s
Rated short-circuit breaking capacity(KA) 6(In≦40A); 4.5(In﹥40A)
Rated residual current breaking capacity(KA) 3
Mechanical & electrical life: 10,000 operations
Installation
protection rating Ip20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2
Tightening torque 2 Nm
Ambient temperature (°C) -5°C ~ +40°C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
pollution degree
installation condition Used in place without obvious shock and vibration
 Weight (g) ≦32A ﹥40A ≦32A ﹥40A ≦32A ﹥40A ≦32A ﹥40A ≦32A ﹥40A
216 240 320 343 445 473 468 518 585 63

Exterior and dimensions

8-LE111

 

 Number  of poles Rated current
<40A ≥40A
Width (mm) Modules Width(mm) Modules
1 /2 45 2.5 54 3
2/2 63 3.5 72 4
3/3 90 5 103.5 5.75
3 /4 99 5.5 117 6.5
4/4 117 6.5 135 7.5




I decide to study the wafer switches on the schematic in hopes of identifying the components that might be responsible for the failure of the AM band. I’ve always found wafer switches intimidating and impossible to fully understand especially in multi-band radios. I have little faith that I’ll do any better with these but I’m hoping a concerted effort with the schematic will payoff with some new insights into the wafer switches in this radio and future radios too.