High Quality for DC miniature circuit breaker-FTBD for Algeria Manufacturer

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

The company upholds the philosophy of "Be No.1 in quality, be rooted on credit and trustworthiness for growth", will continue to serve old and new customers from home and overseas whole-heatedly for High Quality for DC miniature circuit breaker-FTBD for Algeria Manufacturer, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!


Product illustration:

ftbd

Technical Data

Model FTBD DC miniature circuit-breaker
Picture  
Number of poles IP 2P
Rated frequency: AC 50/60Hz
Rated voltage (V) 125/250 250/500
Rated current (A) 1,2,3,4
Rated ultimate short-circuit breaking capacity(KA) 6.5
Rated current (A) 6,10,16,20,25,32,40,50,63
Rated ultimate short-circuit breaking capacity(KA) 20/10 20/10
Rated impulse withstand voltage Uimp(KV) 4
Mechanical and electrical life: 20000
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2, Cross-section of busbar from 0.8-2mm2
Ambient temperature (°C) -25°C ~ +45°
Altitude (m) ≦4000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 116 232

Tripping characteristic

ftbd-5

Exterior  and dimensions

ftbd-6342

Number  of poles 1P 2P
A 80±0.8
B 74.2±0.8 75.7±0.8
C

17.8±0.8

35.6±0.8

D 44±0.8
E

68.7±0.8

70.2±0.8

F 45±0.8
G 35.5±0.8




DB-75 , Westinghouse DB-75 Circuit Breaker , DB-75 3000 amp 600 volt Electrically Operated Class A Reconditioned Circuit Breaker , DB75

800-909-3660 toll free email sales@naswgr.com

http://www.naswgr.com/Circuit_Breaker_Pages/Westinghouse/Low_Voltage/DB-75.html

DB-75
Westinghouse DB-75 Circuit Breaker

3000 amp
600 volt
3 Pole
Electrically Operated
Drawout

Class A Reconditioned with URC AC Pro Solid State Kit
Loose DB-75 circuit breaker parts
Westinghouse DB-75 switchgear

NAS can recondition and retrofit your DB style circuit breakers. Ask about our “Recondition Swapout Program”

Every Class A Reconditioned Westinghouse DB-75 circuit breaker will be tested with report and backed by our 1 year warranty.

http://www.naswgr-store.com/collections/db-breaker-parts.html for more DB parts. We are adding more items everyday.

Westinghouse DB-75 Renewal Parts

Actuator , 692C706G01 ,

Amptector IA Retrofit Kit, 2000-3000 A – LIG , 8184A50G16 ,

Amptector IA Retrofit Kit, 2000-3000 A – LIG (w/o ground indicator) , 8184A50G76 ,

Amptector IA Retrofit Kit, 2000-3000 A – LSG ,8184A50G17 ,

Amptector IA Retrofit Kit, 2000-3000 A – LSG (w/o ground indicator) , 8184A50G77 ,

Amptector IA Retrofit Kit, 2000-3000 A – LSIG , 8184A50G18 ,

Amptector IA Retrofit Kit, 2000-3000 A – LSIG (w/o ground indicator) , 8184A50G78 ,

Amptector IIA Retrofit Kit, 2000-3000 A – LIG , 8184A50G46 ,

Amptector IIA Retrofit Kit, 2000-3000 A – LSG , 8184A50G47 ,

Amptector IIA Retrofit Kit, 2000-3000 A – LSIG , 8184A50G48 ,

Amptectors type IA with indicator – LI , 6998D22G01 ,

Amptectors type IA with indicator – LS ,6998D00G03 ,

Amptectors type IA with indicator – LSI , 6998D22G06 ,

Amptectors type IA with indicator and ground – LI , 6998D02G02 ,

Amptectors type IA with indicator and ground – LS , 6998D02G04 ,

Amptectors type IA with indicator and ground – LSI , 6998D02G05 ,

Amptectors type IIA without indicator or ground – LI , 6997D20G41 ,

Amptectors type IIA without indicator or ground – LS , 6997D20G42 ,

Amptectors type IIA without indicator or ground – LSI , 6997D20G43 ,

Arc Chutes , 405D389G04 ,

Auxiliary Switch, 4 Pole D.O. , 20B834G07 ,

Auxiliary Switch, 8 Pole D.O. , 20B834G08 ,

Breaker Lever , 1799891 ,

Closing Coil 115 vAC , 1809520 ,

Closing Coil 125 vDC , 1809520 ,

Closing Coil 220 vAC , 300P268G01 ,

Closing Coil 250 vDC , 300P268G01 ,

Closing Coil 440 vAC , 300P834G01 ,

Complete Mechanism E/O, 3 Position , 410D348G02 ,

Complete Mechanism E/O, Single Position , 44A9415G06 ,

DB-75, 3 position , 406D349G01 ,

DB-75, single position , 406D444G01 ,

Finger Clusters , 679C711G08 ,

Hinge Contact Finger , 1799912 ,

Latch Segment , 20B8584H04 ,

Lever Spring , 1799968 ,

Levering Crank, 3 position , 303C008G02 ,

Levering Crank, single position , 300C334G01 ,

Lower Stationary Contact Fingers , 1799915 ,

Lower Stud Assembly , 406D445G03 ,

Main Contact , 1810289 ,

Mechanism Shaft , 1799932 ,

Molded Contact Base , 1810282 ,

X Relays 125 V Dc (used with heavy duty burden coils) , 1802990 ,

X Relays 220 V Ac, 60 Hz , 33A2746G35 ,

X Relays 220 V Ac, 60 Hz (used with heavy duty burden coils) , 60A1412G28 ,

X Relays 250 V Dc , 33A2746G33 ,

X Relays 250 V Dc (used with heavy duty burden coils) , 1802991 ,

X Relays 440 V Ac, 60 Hz , 33A2746G36 ,

X Relays 440 V Ac, 60 Hz (used with heavy duty burden coils) , 60A1412G29 ,

Thank you for watching our video

800-909-3660 toll free
216-402-0507 24/7
email- sales@naswgr.com
www.naswgr.com

Related Products