High reputation for Moulded case circuit breaker-FTM2X Wholesale to Kuwait

Overview:



Technical data

Product illustration

Tripping characteristic

Exterior and dimensions

Related video

Persisting in "High quality, Prompt Delivery, Competitive Price", we have established long-term cooperation with clients from both overseas and domestically and get new and old clients' high comments for High reputation for Moulded case circuit breaker-FTM2X Wholesale to Kuwait, We are confident that there will be a promising future and we hope we can have long term cooperation with customers from all over the world.


FTM2X--010202

Model: FTM2X-63
Frame size rated current Inm(A): 63
Poles: 3,4
Rated current(A): 10,16,20,25,32,40,50,63
Rated operational voltage(V): AC380V/400V AC480V/500V AC530V/550V AC660V/690V
Rated insulation voltage(V): AC1000
Rated impulse withstand voltage Uimp(KV): 8
Rated ultimate short - circuit breaking capacity(KV): AC380V/400V 35
Rated  short circuit breaking capacity 25
Rated ultimate short - circuit breaking capacity(KV): AC480V/500V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC530V/550V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC660V/690V 10
Rated  short circuit breaking capacity(KV): 7.5
Operating performance(KV):  Electrical life: 8000
Mechanical life: 20000
Tripping mode(KV): thermomagnetic
Protection category(KV): distribution protection
motor protection
Arcing distance(KV): not more than 50(0)
Isolating function(KV): A
Connection: Front connection plate,rear connection plate,plug-in rear connection plate
Isolating function Yes
Size: L (mm) 130
W(mm) 75/100
H(mm) 90




  • Website:http://www.simplying.com/
    Email: sales@simplying.com
    For years experience . We specialized in Motor Control , breakers, contactors ,PLC,HIM . We major deal with brand of Schneider , Siemens ,Mitsubishi, Allen-Bradley, ABB, GE ,Moeller, Omron, SMC,SICK, LS.



    Please support my content creation by using my Amazon Store:

    http://astore.amazon.com/m0711-20

    Or anything on Amazon:

    http://www.amazon.com/?_encoding=UTF8&camp=212353&creative=380557&linkCode=sb1&tag=m0711-20

    —————————— Click “Show more” ——————————————-
    This is a review and demonstration of the HT Instruments Solar I-V and PV Check solar analyzers.

    http://www.ht-instruments.com/en/products-ht/i-v_curve_tracers_and_pv_testers/solar-i-v

    The IV curve tracer SOLAR I-V has been designed to meet any requirement of photovoltaic installation testers. Further to providing the possibility of testing and measuring the efficiency of single-phase photovoltaic systems and also measures the I-V characteristic both of a single module and of module strings. Thanks to The IV curve tracer SOLAR I-V, the operator can test the photovoltaic system and, should it give a negative result, immediately identify the problems of the system in order to promptly solve them.

    http://www.ht-instruments.com/en/products-ht/i-v_curve_tracers_and_pv_testers/pvcheck

    The multifunction instrument PVCHECK allows prompt and safe electrical checks required for a PV system (section DC) as well as controls on working of modules / strings in accordance with IEC/EN62446 guidelines. PVCHECK verifies the continuity of the protective conductors (and the associated connections) and executes insulation resistance measurement of the active conductors on a module, a string or a photovoltaic field in accordance with the requirements of IEC/EN62446, without the need of short-circuiting the positive and negative terminals. PVCHECK allows verification of a PV string’s working in accordance with the requirements of IEC/EN62446 by measuring the open circuit voltage and short-circuit current under operating conditions and reporting the results to STC (by means of radiation measurement). It provides an immediate outcome for both absolute measurements and for measurements compared with the previously tested PV strings.
    PVCHECK also allows carrying out performance analysis of PV array (DC) under operating conditions (connected to the inverter) providing an indication of the power generated and the efficiency of the field as specified by IEC/EN62446

    ——————————————————————————————————
    My website and forum:- http://www.mjlorton.com
    Donations and contributions:- http://www.mjlorton.com
    My techie channel MJLorton – Solar Power and Electronic Measurement Equipment – http://www.youtube.com/MJLorton
    My Techie Amazon Store: http://astore.amazon.com/m0711-20
    My other channel VBlogMag – For almost any topic under the sun! – http://www.youtube.com/VBlogMag
    My VBlogMag Amazon Store: http://astore.amazon.com/vblogmag-20
    ——————————————————————————————————
    ===================================================
    Video sponsor, Pass Ltd – their websites:
    At checkout use the discount / promotion code “mjlorton” for 5% off.
    http://www.tester.co.uk/?cmid=QmhzQjcxYjVlc1E9&afid=bFcwbzliNzVDc289&ats=K2EyUjZNTDh3UTA9 – Test Equipment and Test-meter suppliers and
    http://www.calibrate.co.uk/?cmid=QmhzQjcxYjVlc1E9&afid=bFcwbzliNzVDc289&ats=S3Yxd2tOMjVISzA9 – Calibration and service of test equipment
    ===================================================
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    Bitcoin (BTC) Donations: 1K7PeF55e7ssE7W3WVCoa7c4j2PHzy6ASv
    $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
    **********************************************************************************
    Music clip from Youtube Music Library – Phase Three by Huma-Huma
    **********************************************************************************

    Related Products

    WhatsApp Online Chat !