It is a good way to improve our products and service. Our mission is to develop creative products to customers with a good experience for Lowest Price for Miniature Circuit Breaker FTB2-63 to Riyadh Manufacturer, We always welcome new and old customers presents us with valuable advice and proposals for cooperation, let us grow and develop together, and to contribute to our community and staff!


Product illustration

gagwq

Technical Data

Model FTB2-63 Miniature circuit-breaker
Number of poles IP 2P 3P 4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

1,2,3,4, 6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated breaking capacity(KA) 6.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm2 , Cross-section of busbar from 0.8- 2mm2,reversibility of connections
Tightening torque 2 Nm
Ambient temperature ( C) -5 C ~ +40 C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 102 208 308 408

Product Feature

- These circuit breakers are intended for the protection of circuits against overloads and short circuits in residential, commercial and industrial premises;

- It covers the rating range from 6 to 63A with a uniform breaking capacity of 6.5 kA throughout;

- Current-limiting scheme: in the event of a short circuit, are able to limit the let-through current to 60%-70%  of the rated current;

- The arc extinguishing system: allows the short-circuit currents of very high value to be interrupted extremely rapidly, the remarkable opening speed of contacts opening and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time;

-The sensitivity and reliability of the trip mechanism ensures perfect closure every time,thereby considerably improving the performance of these devices and extending their average lifetime;

- The internal contact position allows an exact information of the circuit-breaker status:“green”, open contacts;“red”, closed contacts,independently of the toggle position;

- Sealing/locking sealable with 1 mm wire , to prevent unwanted  tripping;

- The supply lines of the protected circuit can be connected to either the upper or lower terminals of the circuit-breakers(reversibility of connections). The double terminal of these circuit-breakers enables simultaneous connection of cables and busbars.

 

Tripping characteristic

qrgadg qweq

Exterior and dimensions

agg

Unit(mm)

Number of poles 1P 2P 3P 4P
a 80±0.8
b 74.2±0.8 75.7±0.8
c 17.8±0.5 35.6±0.8 53.4±0.8 71.2±0.8
d 44±0.8
e 68.7±0.8 70.2±0.8
f 45±0.8
g 35.5±0.8

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A) Nominal cross section area of copper wire(mm2 )
1~6 1
10 1.5
16,20 2.5
25 4
32 6
40,50 10
63 16




  • Electrical Wiring Irvine CA, Call (949) 566-8335 Palmer Electrical Systems

    If you don’t know the difference between the black wire and white wire or don’t know what a ground wire is for, and you need help with your electrical wiring we can help.

    Whether you need to replace a cable or conductors the electrical code is there for your protection and all electrical installations whether an electrical wire or insulated conductors should comply with the national electrical code. Wiring safety codes need to be followed if you are just replacing a switch or need a whole new system.

    If the time of replacing electrical wiring has come. And your electric wiring has timed out, as it only has a limited lifespan. For the record, electric wiring PVC cables have an estimated lifespan of twenty years. By the time twenty years have passed, homeowners are advised to replace their electrical wiring as precautionary measures for the purpose of maintaining a safe home.

    The condition of cables and wires deteriorates over time. If they are used continuously, lives are being recklessly exposed and properties endangered. This is why regular replacement schedules should be followed. Naturally, a licensed electrical technician or electrical engineer can perfectly replace the electrical wiring at home. A licensed electrical technician can determine whether the wirings are no longer safe to use and if so, he can make the necessary replacements.

    Electric wirings are not only to be replaced at the end of their expected lifespans. When electric problems occur, electrical wiring should be replaced right away. To better identify electric problems, one should know first what a consumer unit is and the switches that go along with it. Basically, the consumer unit is responsible for electrical distribution in the panels installed at home. The panels are put together and enclosed. The miniature circuit breakers, or MCBs, are utilized to protect home appliances from electric fault and overheating of cables. When MCBs are switched off or tipped off, the electric supply to the affected circuit is cut off. This usually happens as the result of short circuit, earth-fault, or overload. If electric fault causes too much damage, the replacement of electrical wiring is necessary.

    Fixing the air conditioner is another issue that may require replacing electrical wiring. There are two kinds of air conditioning systems. There is the window-type and there is the split-type. The window-type requires an electric plug for the power source. And, in order to mount it, a boxy rectangular hole-in-the-wall is necessary. On the other hand, the split-type is more complicated to install since its features are more sophisticated. The main two units of split-type units are the internal unit, where the cold air is blown, and the external unit, where the compressor is located. The two units are linked through the pipes to make the air conditioner cold, but the two units need two corresponding power sources. Frequent check-ups and cleaning of the plastic filters are the two simple ways of preventing the problem. If this is done, there is a small chance of experiencing electric failures.

    Replacing electrical wiring is a serious and risky task. If you know the principles of wire replacement, you can save yourself from electric burns and other fatal injuries. This is a situation where being careful is of vital importance. Replacing electric wiring requires that you turn off the power to the circuits and then double check whether it is really switched off. And if you managed to successfully replace everything, such as the electrical receptacles, you need to use testers to know whether the receptacle is already working. Simple steps like these will help keep you and those who visit your home safe. Replacing electrical wiring can be a manageable task if done carefully. And if you are still in doubt of your own capabilities, it is a smart decision to hire a professional electrical technician.

    Please share this video: https://youtu.be/6fXyIpN9vAI

    http://ezinearticles.com/?Learning-About-the-Common-Electrical-Wiring-Questions&id=3153181

    Related Products

    WhatsApp Online Chat !