As a result of ours specialty and service consciousness, our company has won a good reputation among customers all over the world for Manufacturer of Miniature circuit breaker-FTM9-100 to Iran Manufacturer, We sincerely welcome domestic and foreign merchants who calls, letters asking, or to plants to negotiate, we will offer you quality products and the most enthusiastic service,We look forward to your visit and your cooperation.


Model: FTM9-100
Pole: 1P,2P,3P,4P
Rated current (A): 63,80,100
Rated frequency: 50
Rated voltage (V) 230,400
Breaking Capacity: 10
Rated impulse withstand voltage Uimp(KV): 4
Operating cycle times: /hour 120
Power on 4000
Power off 10000
Conventional non-tripping current t≤1h(In=63A) t≤2h(In>63A)
Conventionaltripping current: 1.45In t<1h(In=63A) t<2h(In>63A)
2.55In 1s<t<120s
Instantaneous tripping type: D
Instantaneous non-tripping current: t≤0.1s 10In
Instantaneous tripping current: t<0.1s 20In
Connection Wire ㎜²: Min/Max 16/50
Size(L×W×H) 1P 72×27×85
2P 77×54×85
3P 77×81×85
4P 77×108×85




Electrical Faults ¦ Fault In Electrical Transmission Line ¦ Reason of faults ¦
Hi everybody, today I will share about Electrical Faults.
More videos:-

An electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which current bypasses the normal load. An open-circuit fault occurs if a circuit is interrupted by some failure. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a “ground fault” or “earth fault”, current flows into the earth. The prospective short circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.
There are I explain mainly two types electrical faults.
Symmetric fault. And
Asymmetric fault.

Symmetric fault
A symmetric or balanced fault affects each of the three phases equally. In transmission line faults, roughly 5% are symmetric. This is in contrast to an asymmetrical fault, where the three phases are not affected equally.
Asymmetric fault
An asymmetric or unbalanced fault does not affect each of the three phases equally. Common types of asymmetric faults, and their causes:
line-to-line. a short circuit between lines, caused by ionization of air, or when lines come into physical contact, for example due to a broken insulator. In transmission line faults, roughly 5% – 10% are asymmetric line-to-line faults.
line-to-ground . a short circuit between one line and ground, very often caused by physical contact, for example due to lightning or other storm damage. In transmission line faults, roughly 65% – 70% are asymmetric line-to-ground faults.
Reason of faults.
Insulation failure or break down.
Lighting surge.
Unbalance current or voltage.
Voltage drop.
Stability fall.
Mechanical fault in transmission line.
Over voltage.
Under Frequency.
Reversal of power.
Temperature Rise.

Thanks for watching my learning video. Like Share and comment My videos.
Electrical Faults ¦ Fault In Electrical Transmission Line ¦ Reason of faults ¦
More videos please Subscribe my channel Learning Engineering.
content source by https://en.wikipedia.org/wiki/Fault_(power_engineering)

Related Products

WhatsApp Online Chat !