Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Manufacturing Companies for Moulded case circuit breaker-FTM2X for Anguilla Manufacturer, If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us.


Model: FTM2X-63
Frame size rated current Inm(A): 63
Poles: 3,4
Rated current(A): 10,16,20,25,32,40,50,63
Rated operational voltage(V): AC380V/400V AC480V/500V AC530V/550V AC660V/690V
Rated insulation voltage(V): AC1000
Rated impulse withstand voltage Uimp(KV): 8
Rated ultimate short - circuit breaking capacity(KV): AC380V/400V 35
Rated  short circuit breaking capacity 25
Rated ultimate short - circuit breaking capacity(KV): AC480V/500V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC530V/550V 20
Rated  short circuit breaking capacity(KV) 15
Rated ultimate short - circuit breaking capacity(KV): AC660V/690V 10
Rated  short circuit breaking capacity(KV): 7.5
Operating performance(KV):  Electrical life: 8000
Mechanical life: 20000
Tripping mode(KV): thermomagnetic
Protection category(KV): distribution protection
motor protection
Arcing distance(KV): not more than 50(0)
Isolating function(KV): A
Connection: Front connection plate,rear connection plate,plug-in rear connection plate
Isolating function Yes
Size: L (mm) 130
W(mm) 75/100
H(mm) 90




  • Power Factor Meter 3 Phase 5A 420 V WP 20151014



    Shed Electric Installation
    Cost was about $500.
    10/3 w/ground NM Cable runs from DP 30a breaker in panel, under crawlspace to outdoor box. Transitions to 4 separate conductors of THWN, 10 gauge (H1, H2, N, G)
    18″ Deep 3/4″ PVC conduit
    1 ground rod 8ft long in ground, fed with #6 ground wire as per local code. If water was fed into the building from the house well/plumbing, 2 would be required located 6 ft apart.
    Up into the subpanel, where it is wired up with 14/2 NM cable using 15 amp breakers. Many circuits were added since these are where the interior/exterior lights are also controlled/turned on/off. This lets me lock the subpanel when I have company so no one plays with the lights or breakers, via a cam lock I still have to install on the panel door.