As a result of ours specialty and service consciousness, our company has won a good reputation among customers all over the world for Newly Arrival Miniature circuit breaker-FTBD to Montreal Manufacturers, We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.


Protection rating: IP20
Installation: On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², 
Ambient temperature (°C): Cross-section of conductors up to 25mm²,
Altitude (m): ≦4000m
Relative air humidity: no more than 95%
Pollution degree:
Installation condition: Used in place without obvious shock and vibration
Weight (g): 116 /232




I need help figuring out Ruud furnace error codes.

If all the lights are dead, the problem is the power or lack thereof. Check that the furnace is on, and if so, make sure the fuses aren’t blown or the breaker wasn’t tripped.

It has power. I know that because it tried to start up and now flashes an error code at me.

Ruud furnaces usually try to ignite three times before locking up.

What do I do if it isn’t igniting?

If the unit isn’t igniting, turn off the power and the gas. If it has a honeywell or white rogers valve, turn the knob clockwise to off, and if it is a robertshaw valve, turn the control lever to the off position.

A Nordyne is almost easier – they make the same furnace for everyone.

Not exactly the same – some Nordyne furnaces have only a red light, others red and green, a few with an amber light, depending on the name plate they put on top of it.

Then I can’t use the standard error codes for Nordyne’s furnaces to figure out the Ruud furnace’s blinking at me.

Ruud furnaces typically have a power light that doesn’t flicker unless the voltage wiring is messed up and an okay light that flickers when things are not okay.

So tell me what the blinking means.

One blink is a soft shut down.

And the first solution for a furnace this smart is the same as a gaming console – reboot it.

Two blinks means the pressure switch is stuck open when the inducer is on. You can try to manually close the switch and see if it works after that.

Or replace the switch, which is the cheapest option before paying someone to check the blowers and vents for problems so bad it interferes with the air pressure.

Three blinks means either the limit switch is open or the roll out control is engaged. Four flashes means the pressure switch is closed.

What do five flashes mean?

That means you blinked at the wrong time when it was flashing six times.

I don’t get it.

Most Ruud furnaces, like the more expensive Rheem furnaces that passed quality control, don’t use the five flash error code anymore.

What does the six flash error code mean?

Six flashes means the line and neutral are reversed.

Since I’m not rewiring the furnace in my spare time and it actually ran since installation, that means the grounding for the furnace is messed up.

Or the wiring is otherwise messed up, or the control board is on the fritz.

Then I’m back to rebooting before I give up and pay someone to replace the most expensive parts.



Go to http://www.southlandelectrical.com/itemdesc.asp?ic=SGHA36AT0600-NS&eq=&Tp=&General%20Electric~SGHA36AT0600 to shop online for this General Electric SGHA36AT0600, 600 Amp, 600 Volt, 3 Pole Circuit Breaker. Southland Electrical is a world class leader in Power Distribution and Low Voltage Motor Control. For over 30 years we have been buying and selling New, New Surplus and Reconditioned industrial electrical equipment.