"Control the quality by the details, show the strength by quality". Our company has strived to establish a highly efficient and stable staff team and explored an effective quality control process for OEM/ODM Factory for Miniature circuit breaker-FTB2LE to Cannes Manufacturers, We appreciate your enquiry and it's our honor to work with every friend worldwide.


Product illustration:

ftb2le

 Technical Data

Model FTB2LE Miniature circuit-breaker
Number of poles IP+N,2P,3P,3P+N,4P
Rated frequency: AC 50/60Hz
Rated voltage (V) AC 230/400
Rated current (A) C

D

6, 10, 16, 20, 25, 32, 40, 50, 63

6,10,16,20,25,32,40

Rated residual operating current(mA) AC A 30

30,50,100

Rated residual non-operating current(mA) AC

A

15

15,25,50

Residual current breaking time 30mA≦0.1s  250mA≦0.04s
Max. breaking time(s) 0.1
Rated short-circuit breaking capacity(KA) 6.5
Rated residual current breaking capacity(KA) 4.5
Mechanical & electrical life: 20,000 operations
Protection rating IP20
Installation  
Installation On DIN rail 35mm according to JB6525
Connection capacity: Cross-section of conductors up to 25mm², Cross-section of busbar from 0.8-2mm²,reversibility of connections
Tightening torque 2 Nm
Ambient temperature (°C) - 5°C ~ +40°C
Altitude (m) ≤2000m
Relative air humidity no more than 95%
Pollution degree
Installation condition Used in place without obvious shock and vibration
Weight (g) 340 420 530 630 710

 

Exterior and dimensions

gggggg

Number of poles Width(mm) Modules
1 / 2 54 3
2 / 2 72 4
3 / 3 100 5.5
3 / 4 112.5 6.25
4 / 4 130.5 7.25

 

 

 





  • http://www.eibmarkt.com/de/products/ABB-Stotz-S-J-Sicherungsautomat-proM-Compact-S201P-B10.html
    ABB Stotz S&J Sicherungsautomat proM Compact S201P-B10
    Sicherungsautomat proM Compact S201P-B10 Auslösecharakteristik B, Polzahl (gesamt) 1, Anzahl der abgesicherten Pole 1, Bemessungsstrom 10A, Bemessungsspannung 230V, Spannungsart AC, Frequenz 50 … 50Hz, Überspannungskategorie 3, Verschmutzungsgrad 2, Breite in Teilungseinheiten 1, Einbautiefe 69mm, Schutzart (IP) IP20, Herstellerbestellnummer: 2CDS281001R0105

    http://www.eibmarkt.com/en/products/ABB-Stotz-S-J-Miniature-circuit-breaker-1-p-B10A-S201P-B10.html

    ABB Stotz S&J Miniature circuit breaker 1-p B10A S201P-B10
    Miniature circuit breaker 1-p B10A Release characteristic B, Number of poles (total) 1, Number of protected poles 1, Rated current 10A, Rated voltage 230V, Voltage type AC, Frequency 50 … 50Hz, Over voltage category 3, Pollution degree 2, Width in number of modular spacings 1, Built-in depth 69mm, Degree of protection (IP) IP20, Manufacturer Order number: 2CDS281001R0105

    Herstellerbestellnummer / Manufacturer SKU: 2CDS281001R0105
    EAN: 4016779589581
    Automat, Einbauautomat, Installationsautomat, LS-Automat, LS-Schalter, Leitungsschutzschalter, MCB, Sicherungsautomat, System pro M compact, Verteilereinbaugerät, Überstromschalter, Überstromschutzschalter



    http://www.aaronequipment.com/usedequipment/generators/diesel-gas-fueled/elliott-40rd-43993001 – Used- Elliott 40kW Standby Diesel Generator Set, Model 40RD, Serial BY07J593. Perkins Engine 4.236D. 3/60/208V 12 lead reconnectable. 150 Amp mainline circuit breaker. Coolant heater. Sens battery charger. Weather enclosure. Sub-base fuel tank UL listed. 41 hours. Year 2003. Passed load test 8/1/12