Our company has been focusing on brand strategy. Customers' satisfaction is our best advertising. We also supply OEM service for OEM/ODM Supplier for Miniature circuit breaker-FTM8 to The Swiss Factories, We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!


aaad

Technical Data

Model
FTM8 Miniature circuit-breaker
Number of poles
IP 2P 3P 4P
Rated frequency:
AC 50/60Hz
Rated voltage (V) AC
230/400
 Rated current (A)
C
6, 10, 16, 20, 25, 32, 40, 50, 63
D
6, 10, 16, 20, 25, 32, 40, 50, 63
Rated breaking capacity(KA)
4.5(6~40A),  6(50~63A)
Mechanical & electrical life:
10,000 operations
protection rating
IP20
Installation
On DIN rail 35mm according to JB6525
Connection capacity:
Cross-section of conductors up to 25mm2
Tightening torque
2 Nm
Ambient temperature (C)
-5C ~ +40C
Altitude (m)
≤2000m
Relative air humidity
no more than 95%
pollution degree
installation condition
Used in place without obvious shock and vibration
Weight (g)
106
212
308
426

Tripping Characteristic

aad

Exterior And Dimensions

ssaa

Number of poles
b
e
1P
72
66
2P    3P     4P
75
69

Wiring

Please refer to below table for the connection of wires with a cross section area

Rated current In(A)

Nominal cross section area of copper wire(mm²)

1~6

1

10

1.5

16,20

2.5

25

4

32

6

40,50

10

63

16





VW – 01M Transmission – Solenoid 4 (N91) Open Circuit – Valve Body Repair
On this video we see a very common issue with Valve Body problems on these Volkswagen 01M Transmissions.
Solenoid problems are also very common as you see here. Depending on the issue or the gear that is not performing properly, will lead you to the right direction for diagnosis and repair.
This was a rare instance where it only needed to be repaired without pulling the transmission out of the vehicle. Normally you will see these unit with 4th clutch damage, burned up. When you see that, the valve body needs to be repaired and also the molded pistons have to be replaced along with the normal overhaul kit and bushings.



The Training Series is for Technical Personnels in the Power Industry (PHCN,Eko Electricity Distribution Company, Ikeja Electricity Distribution Company, Ibadan Electricity Distribution Company) that have already installed Crompton Greaves 11KV Circuit Breakers.

Issues relating to tools needed, changing of cirlip, adjusting the ribit, lubrication of rusty parts, changing the mechanism,replaement of the worm gear, adjusting overlap settings for the trip catch would be discussed.

Feel free to contact dipoexcel@yahoo.com for your Crompton Greaves Circuit Breaker Maintenance and Repairs or call +234 803 637 8724.

Related Products

WhatsApp Online Chat !