Our development depends on the advanced equipment, excellent talents and continuously strengthened technology forces. Wholesale 100% Original Moulded case circuit breaker-FTM2-DC Supply to Denver, Welcome to build the well and long standing business relationships with our company to create a glorious future together .customers' satisfaction is our eternal pursuit


<

Frame size Inm(A): 160 250 400 630
Rated current (A): 20,25,32,40,50,63,80,100,125,160, 160,180,200,225,250 250,315,350,400 400,500,630
Poles: 3 4 3 4 3 4 3 4
Rated voltage (V) AC: DC250,DC500,DC750,DC1000
Rated insulationvoltage(V): 1000 1000 1000 1000
Rated impulse withstand
voltage Uimp(KV):
800 800 800 800
Breaking Capacity: S S S S
Ultimate short-circuit capacity Icu (KA) DC250V: 30 / 30 / 30 / 30 /
DC500V: 25 / 25 / 25 / 25 /
DC750V: 15 15 15 20 15 20 15 20
DC1000V: / 10 / 10 / 10 / 10
Service short-circuit capacity
Ics (KA)
DC250V: 75%Icu / 75%Icu / 75%Icu / 75%Icu /
DC500V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC750V: 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu 75%Icu
DC1000V: / 75%Icu / 75%Icu / 75%Icu / 75%Icu
operating performance Electrical life: 3000 3000 1000 1000
Mechanical life: 10000 10000 5000 5000
Arcing distance(mm) No more than 50 No more than 50 No more than 50 No more than 50
Class A
L(mm) 155 165 257 275
W(mm) 90 120 105 140 140 184 210 280
H1(mm) 68.5 69.5 95 95
H(mm) 100 105 154 154




  • Electrical 200 amp service power from pole to garage then feed underground to house 200 A panel. 100 A garage sub panel.From meter base outside to 200 A fused disconnect then feeds splitter.From splitter feeds house panel not shown. Generator to feed to splitter as well. Future to feed solar panels to splitter as well. 2/0 awg cable for 200 amp service. #3 awg for garage 100A panel.



    A ground fault is an unintentional electrical connection between DC and the grounding system of the array. Learn how to troubleshoot the two error messages, EarthCurr and GFDI Open, when a ground fault is detected.

    —-

    SMA America – https://www.SMA-America.com
    SMA Inverted Blog – https://www.SMAInverted.com

    SMA America on Facebook – https://www.facebook.com/SMAAmerica
    SMA America on Twitter – https://twitter.com/SMA_America

    Contact – SocialMedia@SMA-America.com

    SMA Solar Technology AG is a global leader in the development, production and sales of PV inverters and, as an energy management group, offers innovative key technologies for future power supply structures.

    Related Products

    WhatsApp Online Chat !