Air Circuit Breaker-FTW3
Overview:
It is suitable for AC 50Hz 60Hz, rated voltage 400V, 690V, rated current as 200A~6400A, to distribute power and protect line and power equipment from the hazards of overload, undervoltage, short circuit, single-phase grounding and so on.
Model & Spec | FTW3-2000 | FTW3-3200 | FTW3-4000 | FTW3-6300 | ||||||
Frame size current(A) | 2000 | 3200 | 4000 | 6400 | ||||||
Electrical property | ||||||||||
Pole number | 3P/4P | 3P | 3P | 4P | ||||||
Installation mode | Drawer type/fixed type | Drawer type | ||||||||
Rated operating voltage Ue(V) | AC400/690 | |||||||||
Rated current +40℃ In(A) | 200, 250, 315, 400, 500, 630, 800, 1000 |
1250, 1600, 2000 |
2000, 2500, 2900, 3200 |
3600, 4000 |
4000 6400 5000 |
4000, 5000, 6400 |
||||
Rated insulation voltage Ui(V) | AC1000 | |||||||||
Rated impulse withstand voltage Uimp(kV) | 12 | |||||||||
N-pole rated current IN(A) | 100% | - | 50% | |||||||
Breaking capacity | ||||||||||
Rated ultimate short-circuit breaking capacity lcu(kA) | AC400V | 85 | 100 | 100 | 120 | |||||
AC690V | 55 | 65 | 65 | 85 | ||||||
Rated service short-circuit breaking capacity lcs(kA) | AC400V | 85 | 100 | 100 | 120 | |||||
AC690V | 55 | 65 | 65 | 85 | ||||||
Rated short-time withstand current lcw(kA) 1s | AC400V | 65 | 80 | 80 | 100 | |||||
AC690V | 55 | 65 | 65 | 85 | ||||||
Full-breaking time(ms) | 11~22 | |||||||||
Closing time(ms) | <70 | |||||||||
Flashover distance(mm) | 0 | |||||||||
Service life (times) | Mechanical | Maintenance free | 15000 | 10000 | 10000 | 6000 | ||||
Maintenance required | 25000 | 20000 | 20000 | 10000 | ||||||
Electrical | AC400V | 10000 | 7500 | 7500 | 5000 | |||||
AC690V | 10000 | 7500 | 7500 | 5000 | ||||||
Isolation function | ▀ | |||||||||
Protection | ||||||||||
Intelligent controller | ▀ | |||||||||
N-pole protection capacity(4-pole and 3P+N only) | □ | |||||||||
Connection and installation | ||||||||||
Use cat. | B | |||||||||
Class of pollution | 3 | |||||||||
IP rate | IP30 | |||||||||
Installation cat. | Circuit breaker(include primary side coil) | IV | ||||||||
Auxiliary circuit(exclude primary side coil) | III | |||||||||
Connection mode | Horizontal/Vertical | |||||||||
Inlet method | Upper/lower | |||||||||
Installation mode | Fixed type | Drawer type | Fixed type | Drawer type | Drawer type | |||||
Outline dim.(mm) | Width | 362/457 | 375/470 | 422/537 | 435/550 | 550 | 813 928 928 | |||
Height | 402 | 433 | 402 | 433 | 433 | 433 433 433 | ||||
Depth | 323 | 421 | 368 | 468 | 494 | 494 494 494 | ||||
Weight(kg) | 3P | 56 | 86 | 70 | 110 | 145 | 185 | 220 | ||
4P | 65 | 98 | 82 | 135 | - | 220 |